With its extruded polystyrene (XPS) construction, Kingspan GreenGuard XPS Residing Board does not absorb water, is not a food source for mold, and is not subject to moisture-related damage and deterioration. An R-Value of 5.0 per inch of thickness makes it an excellent thermal insulator that increases the energy efficiency of your structures, and it retains its insulating properties over time. The board also provides an extra barrier against moisture infiltration. Choose between a square edge (CM) and an interlocking shiplap edge (SL) that helps reduce air leaks at seams and gaps.

  • Highest thermal performance
  • R–value of 5.0 per inch of thickness provides excellent energy efficiency
  • Water absorption of only 1/10% by volume

Product Information

Typical Physical Properties
Property Test Method 1/2"
Nominal Thickness
3/4" 1"
Thermal Resistance, R-Value1
(oF-ft2-h/Btu)
ASTM C 518
(@ 75oF Mean Temperature)
3.0 4.0 5.0
Water Vapor Permeance
(perm)
ASTM E 96
Procedure A
(75ºF, 50% R.H.)
0.8 0.8 0.8
Water Absorption
(max,% by Volume)
ASTM C 272 0.1 0.1 0.1
Fire Characteristics2
Flame Spread
Smoke Developed
ASTM E 84/UL 723 10
60-200
10
60-200
10
60-200
Max. Recommended
Use Temp (ºF)
  165 165 165
Dimensions / Packaging
Board Dimensions 2' x 8' 2' x 8' 2' x 8' 4' x 8' 4' x 8' 4' x 8'
Thickness
1/2"
Nominal
Thickness
3/4" 1" 1/2"
Nominal
Thickness
3/4" 1"
Pieces/Bundle 20 14 16 20 14 12
Pieces/Pallet 320 252 192 160 126 96
Square Feet/Pallet 5,120 4,032 3,072 5,120 4,032 3,072

1 Specimens are aged and tested in accordance with the FTC “R-Value Rule” (16 CFR, Part 460) and ASTM C 578 (1″ only).
2 These numerical flame spread and smoke ratings are not intended to reflect hazards presented by this material under actual fire conditions. See UL Classification Certificate A183.

GreenGuard Siding Underlayment Line Sheet

GreenGuard Siding Underlayment Line Sheet

NGBS Green Certification- XPS Insulation Board

NGBS Green Certification- XPS Insulation Board

GreenGuard XPS Residing Board Installation Guide ESP

GreenGuard XPS Residing Board Installation Guide ESP

GreenGuard XPS Insulation Board Safety Data Sheet

GreenGuard XPS Insulation Board Safety Data Sheet

Fav Faved
Kingspan GreenGuard Technical Evaluation Report TER No. 1011-01

GreenGuard Technical Evaluation Report TER No. 1011-01

Kingspan GreenGuard Technical Evaluation Report TER No. 1407-05

GreenGuard Technical Evaluation Report TER No. 1407-05

TER 1410-09 Sheathing_IMG

GreenGuard Technical Evaluation Report TER No. 1410-09

GreenGuard XPS Insulation Board Technical Bulletin #7

GreenGuard XPS Insulation Board Technical Bulletin #7

GreenGuard IECC Reference Guide Technical Bulletin #15

GreenGuard IECC Reference Guide Technical Bulletin #15

GreenGuard Type IV XPS Insulation Board Technical Bulletin #18

GreenGuard Type IV XPS Insulation Board Technical Bulletin #18

Do you need assistance selecting the right product?

Our teams are dedicated to helping make the process as easy as possible and ensure you get the right materials for your needs.

Contact Us

Kingspan Insulation North America

Head Office & Sales Office – North America

Kingspan Insulation LLC

2100 Riveredge Parkway, Suite 175

Atlanta, Georgia

USA

30328

Call: 1 800 241 4402

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

If you do not click "Accept and close" and continue to use this website, we will assume that you consent to our use of cookies.