What Is Virtual Containment?

In-Floor Cooling With Directional Airflow Panels and Controls

At it's core, virtual containment uses a system of products to ensure delivery of the right amount of air, as it is needed, directly to your data center's equipment. This is achieved through a combination of directional airflow panels, airflow control devices, and doors at the end of the aisle which eliminates nearly all bypass air and provides an effective data center containment solution without the need for a roof.

Benefits of a virtual containment solution are:

  • First cost savings over other containment strategies
  • Comparable cooling capacity to physical containment
  • Resolution of the fire suppression, light, or service distribution concerns associated with the addition of a roof in a physical containment solution
What follows is a more detailed look at how virtual containment and directional airflow can work for your data center.

A History of Data Center Containment

Physical Containment
Historically, data centers operating with a raised access floor system have utilized traditional airflow panels coupled with aisle containment for their server rack cooling needs. These airflow panels would supply air in a vertical plume, which has been shown to result in a bypass airflow rate –  air that is delivered into the data center but not consumed by the equipment and exhausted as waste heat – of 50% or more. It was this limitation which necessitated the development of physical containment systems as a solution to reduce bypass airflow and maximize the amount of airflow which could be captured and used to cool equipment is maximized.

But physical containment can bring its own set of challenges as it requires a roof to be installed to be effective, which limits the flexibility of the build, increases overall cost, and impacts fire suppression, lighting, and other data centre service distribution concerns.

Virtual containment is an increasingly popular solution to this challenge, which focuses on solutions that deliver the right amount of air directly to the equipment, maximizes design flexibility and allows data centres to operate more efficiently.

How Does Virtual Containment Work?

Virtual Containment
Unlike physical containment systems, virtual containment utilizes directional airflow panels which angle airflow toward the face of the rack, nearly eliminating bypass air while increasing cooling capacity and energy efficiency. These panels can achieve a 93% Capture Index – the amount of air delivered through the panel that directly enters the face of the server rack in front of that panel – significantly reducing the amount of bypass air.

Additionally, advances in directional airflow panel design have introduced multi-directional panels where airflow is split evenly and angled in two directions. This allows for delivery of directional airflow to racks on either side of a cold aisle in a legacy data center that has only one accessible airflow panel. And, for applications where less airflow is required but directionality is needed to more precisely match cooling with heat loads, perforated directional panels are available.

Using a directional panel can save more than 40 percent in fan energy by enabling a rack with equal load to be effectively cooled, using approximately half the CFM of a conventional panel. With less air required and higher Delta Ts, fewer computer room air-handling (CRAH) units may be needed in a new data center, reducing initial capital expenditures by up to 40 percent. In retrofit applications, CRAH units with fixed-speed fans can be set to standby mode, or variable-fan drives can be adjusted to operate at a lower static pressure, saving energy.

Localized Cooling Controls for Variable Loads

Vertical Containment
Even greater efficiency can be achieved by pairing directional airflow panels with a variable-air-volume damper. Integrating this technology with directional airflow panels into the raised access floor of a data center creates a cost-effective method for achieving the diverse cooling needs of rack specific heat loads in a variable-load environment.

Thermostatically controlled VAV dampers use sensors mounted to the face of the rack to control the damper and adjusts the amount of airflow moving through the panel. The resulting panel-to-rack alignment provides localized cooling to the real-time heat load of the rack, and ensures that proper inlet air temperature is maintained on a rack-by-rack basis.

Future-Proof Data Center Design

Tate_Green_SpotlightImage
The future of data centers will inevitably continue to evolve as cooling and service distribution needs in the data center sector change. Raised floors have been used throughout the history of data centers because of their ability to enable facilities to address often unforeseeable advancements in technology, and the virtual containment solution continues that trend.

When virtual containment is utilized and directional airflow panels are partnered with control devices and doors at the end of the aisle, bypass air can be nearly entirely eliminated, and the system provides containment without the need for a roof or other overhead partitions.

The end result? A future-proof data center environment which offers an excellent high-efficiency, cost-minimizing solution for new data centers, as well as an affordable easy-to-retrofit solution for existing raised floor facilities. 

Explore Directional Airflow Panel Options

Explore Airflow Control Options

Learn How Virtual Containment
Can Help Your Data Center

Read More About Tate Data Center Solutions

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click “Accept and close” to accept the use of cookies on our website. If you do not click “Accept and close” but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.