Multi-Zone Opposed Blade Damper

Multi-Zone Opposed
Blade Damper

Efficiently manage airflow to partially deployed racks

The Multi-zone Opposed Blade Damper allows for delivery of air only to where load is present, and confining airflow to where there is none. The reduction in airflow volume as a result of closing off airflow to unused sections of racks reduces energy expenditure at the CRAC unit level.

Field-mounted Multi-zone Opposed Blade Damper
Previous
Next

Key Performance Characteristics

  • Provides more airflow at 100% than comparable slide dampers
  • Easily adjustable from above without panel removal
  • Quarter turn adjustment for 0-100% range
  • For use with full or partial loaded racks
  • Field-mounted dampers are attached to the bottom of the airflow panel
  • Field-mounted Multi-zone dampers are for use with DirectAire Al and DirectPerf 32% panels
  • Drop-in damper design is for use with DirectAire and allows for easy retro

Multi-zone Opposed Blade Damper

AU_Datacenter_AirflowControls_MultizoneOBD_multi-zoneSpotlightImage
The Multi-zone Opposed Blade Damper enables individuals responsible for the physical infrastructure to deliver air where the IT user has servers and equipment installed, but restrict airflow delivery into zones where no blanking panels and no equipment is installed. Divided into three zones, (top, middle and bottom) each zone of the manual damper can be adjusted from the surface without removing the Airflow panel for fast accurate balancing to the fixed IT loads.

Product Resources & Downloads

Multi-Zone Opposed Blade Damper Datasheet

Multi-Zone Opposed Blade Damper DirectAire Datasheet

Multi-Zone Opposed Blade Damper Detail (PDF)

Multi-Zone Opposed Blade Damper Detail (CAD)

Multi-Zone Opposed Blade Damper Specification

Multi-Zone Opposed Blade Damper DirectAire Specification

The Multi-Zone Opposed Blade Damper is available with these airflow panel options

Brochures-In-Floor-Cooling

In-Floor Cooling Solutions for Data Centers

Brochures-Data-Center-Opt

Data Center Optimization Solutions

Other Airflow Control Options

Other Data Center Solutions

More About Tate

Need to talk? We're here for you.

Our team is ready to help you select the best solutions for your project.

Contact our support team

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click “Accept and close” to accept the use of cookies on our website. If you do not click “Accept and close” but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.

The Cookie Policy & Control and Website Privacy Notice were updated on 13 August 2018.