WinCo_Foods_Boise_ID_07_200IR_300MNR_KSMFHF_US

200 Inverted Rib Wall Panel

Download
200 Inverted Rib CS Intermediate Support 200 Inverted Rib CS Intermediate Support
Previous
Next

200 Inverted Rib Wall Panel

The 200 Inverted Rib panel is perfectly suited for controlled environment applications including food processing, pharmaceutical production and cold storage. The 42” cover width allows for simple installation and fast building close in. With insulation up to 6” thick, the 200 Inverted Rib panel provides superior thermal performance. 

  • Foamed-in-place manufacturing process produces consistent high quality
  • Tested R-Value of 8.25 per inch per ASTM C518 @ 35°F
  • Available finishes meeting USDA standards
  • Highly attractive compliment to pre-engineered building systems
  • 200 Inverted Rib is the panel of choice for freezer/cooler applications
  • GREENGUARD Gold Certified
200_Inverted_Rib_Cold_Storage_Profile_Render_200IR_US

Product Information

Technical Information
Performance Testing & Approvals
Warranty
Colors
Profile Exterior: Inverted Rib
Interior: Minor Rib, Shadowline or V-groove
Embossing Exterior: Stucco or non-embossed
Interior: Stucco or non-embossed
Gauge Exterior: 26, 24, 22 ga
Interior: 26, 24, 22 ga
Width 42”
Thickness 2", 2.5", 3", 4", 5", 6"
Length 8' - 53'
Reveal option N/A
Orientation Vertical
Post fabrication N/A
R-value ≈ 7.2 per inch per ASTM C518 @ 75˚F
≈ 8.25 per inch per ASTM C518 @ 35°F
Test Procedure Results
Fire FM-4880 Class 1 Fire Rating of Insulated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings, and Exterior Wall Systems
ASTM E84 Flame Spread: 25 or Less / Smoke Developed: 450 or Less
ULC-S101 Standard Methods of Fire Endurance Tests of Building Construction and Materials
ULC-S102 Standard Method of Test for Surface Building Characteristics of Building Materials and Assemblies
ULC-S127 Standard Corner Wall Method of Test for Flammability Characteristics of Non-Melting Building Materials
UBC26-4 / NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
NFPA 259 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
Strength FM-4881 Approval Standard for Class 1 Exterior Wall Systems
ASTM E72 Chamber Method Panel load / span and deflection tables are available
Thermal Transmission ASTM C518
Thermal Performance at 75°   Thermal Performance at 35°
Thickness U-Factor R-Value Thickness U-Factor R-Value
2 0.07 14.4 2 0.06 16
2.5 0.06 18.0 2.5 0.05 20
3 0.05 21.6 3 0.04 24
4 0.03 28.8 4 0.03 32
5 0.03 36.0 5 0.03 40
6 0.02 43.2 6 0.02 48
Air Infiltration ASTM E283 0.003 CFM/ft² of Panel Area at 6.24 psf
Water Penetration ASTM E331 No Water Penetration at 20.0 psf
Fatigue Subjected to 2 million alternate cycles of 20 PSF positive and
negative wind loading
No metal / foam delamination or metal fatigue
Humidity Sample subjected to 100% relative humidity at 140°F for 1000 hours No evidence of metal primer corrosion
Autoclave Sample placed in an autoclave device and pressurized to 2 PSI
at 212°F for 2½ hours
No evidence of delamination
Skin Delamination   No skin delamination with direct pull off pressure up to 1188 psf


Product reliability is critical, particularly in controlled atmosphere applications where the challenges of meeting the climatic extremes require special know-how and experience.  For peace of mind, our teams offer comprehensive guidance and expertise during the design and construction phases of the project and are backed by Kingspan’s broad coverage warranties:
 

  • 2 year standard material workmanship warranty
  • Up to 20 years standard finish warranty
 
Contact our sales or customer service departments for information regarding our optional warranty programs.
 

Insulated_panel_systems_colors

Downloads

Controlled Environments Product Selector

Color Chart

HERCULES Door Brochure

Be Inspired Global Case Study Book

200 Inverted Rib Data Sheet

200/300 Series Span Table

200 Inverted Rib Weight Table

200/300 Series MasterFormat CSI Specification (DOC)

200/300 Series MasterFormat CSI Specification (PDF)

200/300 Series Cold Storage CAD Details (DWG)

200/300 Series Cold Storage CAD Details (PDF)

Featured Projects

For the complete controlled environments building envelope solution, consider these complementary products.

Support & Training

Can we help or provide a sample?

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click “Accept and close” to accept the use of cookies on our website. If you do not click “Accept and close” but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.

The Cookie Policy & Control and Website Privacy Notice were updated on 13 August 2018.