Diamond_Head_Storage_Honolulu_HI_01_DW2000S_US

Designwall Wave

Download
Designwall Wave Intermediate Support Designwall Wave Intermediate Support

BENCHMARK Designwall Wave Architectural Wall Panels

Designwall Wave architectural wall panels portray a continuous sweeping profile that creates beautiful shadowing effects. With a distinct joint design, Designwall Wave allows for horizontal and vertical installation with exceptional foam-to-foam contact. A wide variety of colors and finishes are available including metallics and micas.

  • Available in lengths ranging from 8’ – 52’
  • R-value of 7.2 per inch (at low cell) provides superior thermal  performance
  • Single component design increases build speed over multi-part system by up to 50%
  • Tested in accordance with UL, FM and ASTM approval standards, testing methods and procedures
  • 39 3/8” module width allows for fast building close in
  • GREENGUARD Gold Certified
BENCHMARK_Designwall_Wave_Profile_Render_DWW_NA

Product Information

Technical Information
Performance Testing & Approvals
Warranty
Colors
Exterior profile Wave with stucco embossing (optional non-embossed)
Interior profile V-groove with stucco embossing
Exterior gauge 22 ga
Interior gauge 26, optional 24 or 22 ga
Widths 39 ⅜” (1 meter)
Lengths 8’ - 52’
Thicknesses 2”, 3”, 4”
Reveal options N/A
Post Fabrication N/A
R-value ≈ 7.2 per inch (at low cell) per ASTM C518 @ 75˚F
Orientation Horizontal or Vertical
Test Procedure Results
Fire FM-4880 Class 1 Fire Rating of Insulated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings, and Exterior Wall Systems
ASTM E84 Flame Spread: 25 or Less / Smoke Developed: 450 or Less
CAN / ULC-S102 Standard Method of Test for Surface Building Characteristics of Building Materials and Assemblies; Flame Spread: 20; Smoke Developed: 280
CAN / ULC-S127 Standard corner wall Method of Test for Flammability Characteristics of Non-Melting Foam Plastic Building Materials; Flame spread: 490
CAN / ULC-S138 Standard Method of Test for Fire Growth of Insulated Building Panels in a Full Scale Room Configuration; NOTE: The panels are permitted in a non-combustable construction, provided the building is sprinklered
NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
NFPA 259 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
Toxicity State of New York, Article 15, Part 1120 of the New York State
Uniform Fire Prevention Code
Kingspan panels are in compliance
Strength ASTM E72 Chamber Method Panel load / span and deflection tables are available
Thermal Transmission ASTM C518
Thermal Performance at 75°  
Thickness K-Factor R-Value
2 0.1407 14.8
3 0.1304 22.2
4 0.1351 29.6
Air Infiltration ASTM E283 0.003 CFM/ft² of Panel Area at 6.24 psf
Water Penetration ASTM E331 No Water Penetration at 20.0 psf
Fatigue Subjected to 2 million alternate cycles of 20 PSF positive and negative wind loading No metal / foam delamination or metal fatigue
Humidity Sample subjected to 100% relative humidity at 140°F for 1000 hours No evidence of metal primer corrosion
Autoclave Sample placed in an autoclave device and pressurized to 2 PSI at 212°F for 2½ hours No evidence of delamination
Skin Delamination   No skin delamination with direct pull off pressure up to 1188 psf


In today’s challenging construction market, realizing the customer’s requirements often involve leaving the past behind and stretching the boundaries forward. Kingspan products and services are engineered to provide the confidence necessary to meet these challenges.  
 
BENCHMARK By Kingspan insulated metal wall panels have been used on every continent in the world under extreme climatic conditions and are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, ensuring long-term reliability and service life.
 

  • 2 year standard material workmanship warranty
  • Up to 20 years standard finish warranty
 
Contact our sales or customer service departments for information regarding our optional warranty programs.
 

BENCHMARK_colors

Downloads

BENCHMARK Black Book

BENCHMARK Product Selector

Color Chart

BENCHMARK Specialty Finishes & Precious Metals Brochure

Be Inspired Global Case Study Book

BENCHMARK Designwall Wave Data Sheet

BENCHMARK Designwall Wave MasterFormat CSI Specification (DOC)

BENCHMARK Designwall Wave MasterFormat CSI Specification (PDF)

More from BENCHMARK

Support & Training

Can we help or provide a sample?

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

If you do not click "Accept and close" and continue to use this website, we will assume that you consent to our use of cookies.