IBEW_ll86_Training_Facility_Kahului_HI_01_DW2000R_DW2000S_USA

Designwall R Series

Download
Designwall R Series Intermediate Support Designwall R Series Intermediate Support

BENCHMARK Designwall R Series Architectural Wall Panels

Designwall R Series architectural wall panels provide a profiled, accent version of BENCHMARK's Designwall 2000 wall panel with variable rib configurations at 7/8" deep. Variable rib configurations are available in module widths of 12”, 16”, 20” and 24”. Designwall R Series interfaces and engages with other Designwall horizontal panel profiles to create a distinct accent.

  • All thickness options engage with Flushglaze 4500 and 7500 integral window systems
  • Panel lengths available as long as 20’ and as short as 4’
  • Designwall R Series joint perfectly matches Designwall 2000, 4000 and Shadowline
  • .040” stainless steel option available for exterior and interior skins
  • Completely integrates with extruded or anodized aluminum design louvers
BENCHMARK_Designwall_R_Series_Profile_Render_DWRS_NA

Product Information

Technical Information
Performance Testing & Approvals
Warranty
Colors
Exterior profile Ribbed with stucco embossing (optional non-embossed or Granitstone)
Interior profile Flat with stucco embossing (optional non-embossed)
Exterior gauge 22 ga
Interior gauge 22 or 24 ga
Widths 12”, 16”, 20” or 24”
Lengths 4” - 24’
Thicknesses 2.5”, 3”, 4”
Reveal options N/A
Post Fabrication Transverse bends, end caps, curves
R-value ≈ 7 per inch per ASTM C1363
Orientation Horizontal or Vertical

 
Test Procedure Results
Flammability FM-4880 Passed: Class 1 Fire Rating of Insulated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings, and Exterior Wall Systems 2” thru 6”
  ASTM E84 Flame spread <25, smoke developed <450
CAN/ULC-S101 Fire endurance tests: 10 min stayed in place
CAN/ULC-S102 Flame spread: 20, Smoke developed: 145 for panel with facings
CAN/ULC-S127 Flame spread: 435 for foam core
CAN/ULC S134 Passed: standard method of test for fire of exterior wall assemblies
UL 263 Classified as component of 1 hr, 2 hr, or 3 hr fire-rated wall assembly
NFPA 259 Tested for potential heat of building materials 12,448 BTU/lb.
NFPA 268 Passed: standard test method for determining ignitability of exterior wall assemblies using a radiant heat energy source
NFPA 285 Passed: standard fire test method for evaluation of fire propagation characteristics of exterior non-load-bearing wall assemblies containing combustible components in multi-story applications
Structural FM-4881 Passed: Class +65 / -91 Zone TC
ASTM E72 Vacuum chamber tested. Panel load / span and deflection tables are available
TAS 201, 202, 203 Testing to +/- 80 psf. on 36” wide panels
Blast Loading ASTM F1642 or GSA-TS01 Panels installed on metal stud system shall be tested to withstand a minimum shock load of 6 psi peak pressure and 42 psi-msec impulse pressure
Thermal Transmission ASTM C518 or ASTM C1363
Thermal Performance at 75˚
Thickness R-Value
2.5 11
3 14
4 22
Air Infiltration ASTM E283 0.01 CFM/ft² of panel area at 20 psf
Water Penetration ASTM E331 No uncontrolled water penetration at 70 psf. differential pressure. No water penetration at 6.24 psf pressure differential for a two (2) hour duration.
AAMA 501.1 Dynamic water pressure testing – no sign of water leakage at 15 psf
Water Absorption ASTM C209 No more than 0.127 percent water absorption by volume under  24-hour full water submersion
Fatigue Tests Cyclic test to positive and negative wind loading to ± 20 psf The panels exceeded 2 million alternate cycles without failure or damage
Bond Strength Autoclave Sample placed in an autoclave device and pressurized to 2 PSI at 217 °F for 2 ½ hrs
Humid aging No metal primer interface corrosion and/or delamination shall occur after 1000 hours at 135˚F and 100 percent relative humidity
Regional Approvals Miami-Dade Listing N.O.A. # 16-0329.09 (expires 05/18/2022)
  City of Los Angeles LARR #26046
UL Canada Listing File # R19992
Intertek Listing CCRR Report #1037
Florida Product Approval FL 20453.1-R1


In today’s challenging construction market, realizing the customer’s requirements often involve leaving the past behind and stretching the boundaries forward. Kingspan products and services are engineered to provide the confidence necessary to meet these challenges.  
 
BENCHMARK By Kingspan insulated metal wall panels have been used on every continent in the world under extreme climatic conditions and are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, ensuring long-term reliability and service life.
 

  • 2 year standard material workmanship warranty
  • Up to 20 years standard finish warranty
 
Contact our sales or customer service departments for information regarding our optional warranty programs.
 

BENCHMARK_colors

Downloads

BENCHMARK Black Book

BENCHMARK Product Selector

Color Chart

BENCHMARK Specialty Finishes & Precious Metals Brochure

Be Inspired Global Case Study Book

BENCHARMK Designwall R Series Data Sheet

BENCHMARK Designwall Weight Table

BENCHMARK Designwall Wind Loads and Span Tables

BENCHMARK Designwall 2000 Guide Specification (DOC)

BENCHMARK Designwall 2000 Guide Specification (PDF)

Designwall 2000 Horizontal CAD Details (DWG)

Designwall 2000 Horizontal CAD Details (PDF)

Designwall 2000 Vertical CAD Details (DWG)

Designwall 2000 Vertical CAD Details (PDF)

BENCHMARK Designwall 2000/4000 Installation Guide

Featured Projects

More from BENCHMARK

Support & Training

Can we help or provide a sample?

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

If you do not click "Accept and close" and continue to use this website, we will assume that you consent to our use of cookies.