Heat protection
For maximum thermal protection performance: Heat transfer coefficients according to EN 14509 A.10
Environmental
To the environment, our career panel elements react chemically neutral and give mold and rot no chance. The insulating core is, of course, odorless and absolutely safe for your stay and health.
Fire protection and fire behavior
Our career panel elements meet the high requirements and tests of the national technical regulations and standards. The safe fire behavior of the panels with the FireSafe IPN insulation core has been classified according to EN 13501-1 in class B-s1, d0. For further information on fire resistance please contact our technical service department.
Soundproofing
Without additional measures, our Carrier panel elements achieve an evaluated noise reduction of Rw = 25dB.
Technical regulations and standards
Our carrier complies with the technical requirements of DIN EN 14509: Self-supporting sandwich elements with metal top layers on both sides. In Germany, the system is approved by the building authorities under the number Z-10.49-581.