Product Highlights

Comprised of high-strength steel cable supported on energy-absorbing roof anchor posts, limiting the fall arrest roof load to less than 6kN. 

1. Fully compliant with BS EN 795: C.
2. Incorporates force minimisation technology.
3. Corrosion resistant.
4. No access to roof underside required.   
5. Designed for use with Kingspan roof panels and PV.
6. Can be installed during or after construction.
7. Guaranteed for up to 15 years.
Safepro2 profile

Technical Details


Fully compliant with AS NZS 1891.2 & 1891.4, BS EN 795: D and OHSA 1926
 
Available with the Kingspan Guarantee.
 
Compatible with most Kingspan insulated roof panels. 
 

  Trapezoidal Lo-Pitch Curved Roof K-Dek Topdek KingZip SF
Safepro2
PPE Level Summary Description Application Example
1 Restraint without requirement for PPE adjustment.  Workers are restrained from reaching all fall hazards by attaching themselves to the fall protection system with PPE that requires no manual adjustment. 

The system, as installed, should be proven capable of arresting falls. 
System is fixed 2.5m back from the edge of a low pitch roof. 

Worker is using a 2m long lanyard. 

Within 5m of the roof edge, the worker is restrained from reaching the edge without the need to adjust PPE. 

For roof locations over 5m from the edge, there is negligible risk of a fall. There is no need for PPE attachment. 
 
2 Restraint with requirement for PPE adjustment.  Workers are restrained from reaching all fall hazards by attaching themselves to the fall protection system with PPE that requires correct manual adjustment. 

The system, as installed, should be proven capable of arresting falls. 
System is fixed centrally on a roof. 

Worker uses a rope with a grab. 

For protection when accessing different areas of the roof, workers should manually adjust the length of their connection to the system. 

Incorrect adjustment may result in a fall. 
 
3 Fall arrest.  Workers are not restrained from reaching fall hazards, but any fall occurance will be arrested in a controlled manner. 

Fall clearance must be taken into consideration, and a rescue plan must be implemented before work begins. 
 
A narrow roof area where it is not possible to prevent workers from reaching the edge, even when they are connected to a fall protection system. 
In a single unique package, we cover the performance of your insulated panels and ancillary products in the following areas:
 
  • Coating performance - up to 15 years
  • Fire performance - up to 15 years
  • Thermal performance - up to 15 years
  • Structural performance - up to 15 years
  • Acoustic performance - up to 15 years

Downloads

Kingspan Fall Protection Systems Brochure

System Design & Services

We manufacture and support the complete roof and wall system including construction details (see CAD details). Contact us for complementary services including: project specific specifications, advice on fire, thermal, condensation and structural performance along with review of bespoke construction details.
Flat Roof System

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click "Accept and close" to accept the use of cookies on our website. If you do not click "Accept and close" but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.

The Cookie Policy & Control and Website Privacy Notice were updated on 13 August 2018.