Kooltherm K15 Cladding Board has a fibre-coree and is faced on both sides with a composite foil
Previous
Next

Why Kingspan Kooltherm K15?

Kingspan Kooltherm K15 Cladding Board is a premium performance rigid thermoset phenolic insulation faced on both sides with a low emissivity composite foil.

Kingspan Kooltherm K15 Cladding Board can be used within insulated cladding facades.

Kooltherm insulation has a fibre-free and closed cell insulation core, which has been manufactured with zero Ozone Depletion Potential and low Global Warming Potential.
  • Excellent thermal performance
  • Fibre-free core
  • Zero ODP & low GWP
  • Exceptional fire performance: successfully tested to BS8414 and NFPA 285         

Product Information

Product Data
Testing and Compliance
Management Standards
Fire and Smoke Performance
Environmental Data
U-values
Specification

Product Data

Property Value
Board Size 1.2 x 2.4 m
Facings Low emissivity composite foil
Core Premium performance fibre-free rigid thermoset phenolic insulant manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP).

Testing and Compliance

Test Standard Result
Thermal Conductivity (λ-Value) ​ ASTM C518 0.020 W/m.K
Density BS EN 1602: 2013 35 kg/m3
Compressive Strength BS EN 826: 1996 120 Kpa @ 10% compression
Cell Gas Analysis N/A CFC/HCFC-free
Dubai Central Laboratory (DCL) N/A Approved
Abu Dhabi Quality and Conformity Council (ADQCC) N/A Certified
State of Qatar Ministry of Interior General Admin of Civil Defence N/A Approved

Management Standard

Standard Management Standard
ISO 9001:2015 Quality Management
ISO 14001:2015 Environmental Management
BS OHSAS 18001:2007 Health and Safety Management
ISO 50001: 2011 Energy Management

Fire and Smoke Performance

Test Standard Result
Fire Performance of External Cladding Systems  BS8414-1 & BS8414-2 Successfully tested in differing façade systemsin accordance with the performance criteria set out in BR 135 
Fire Performance of External Cladding Systems  NFPA 285  
Surface Burning Characteristics (Insulation Core) UL 723 Flame Spread Index of ≤25
Smoke Developed Index (SDI) of ≤50
Class 1/A
Surface Burning Characteristics ASTM E 84 Flame Spread Index of ≤25
Smoke Developed Index (SDI) of ≤50
Class 1/A

Environmental Data

Standard Result
Green Guide Rating A+
BES 6001 Excellent

U-value Reference Table

U–values for Various Thicknesses of Kingspan Kooltherm K15 Cladding Board behind a cladding system on a 200 mm Concrete Block Wall
Insulant Thickness (mm) U−values (W/m2.K)
30 0.53
35 0.48
40 0.44
45 0.40
50 0.38
55 0.35
60 0.33
65 0.31
70 0.30
80 0.27
85 0.26
90 0.25
95 0.24
100 0.23

Kingspan Kooltherm K15 Cladding Board should be described in specifications as:

The external wall insulation shall be Kingspan Kooltherm K15 Cladding Board ____ mm thick: comprising a fibre–free premium performance rigid thermoset phenolic insulation core faced on both sides with a low emissivity composite foil. The Insulation core shall be 90% (or greater) closed cell structure. The product shall be manufactured: with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP); under a management system certified to ISO 9001: 2015, ISO 14001: 2015, BS / I.S. OHSAS 18001: 2007 and ISO 50001: 2011; by Kingspan Insulation and installed in accordance with the instructions issued by them.
 

Download Product Information

Front Cover_ Kooltherm K15 Literature

Kooltherm K15 Literature

More details for K15

Featured Case Studies

Do you need help and advice on your project?

Our teams are dedicated to helping make your process as easy as possible and ensure you get the right materials for your building.

Contact us

Contact Information

Kingspan Insulation Middle East

Kingspan Insulation operates across the Middle East, Africa and Indian Subcontinent. Contact us to find your local representative. For any inquiries send an email to info@kingspaninsulation.ae

Head Office

P.O. Box 113826, Dubai Investment Park 2

Dubai, U.A.E.

Tel: +971 4 889 1000

Fax: +971 4 883 8515

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click "Accept and close" to accept the use of cookies on our website. If you do not click "Accept and close" but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.

The Cookie Policy & Control and Website Privacy Notice were updated on 13 August 2018.