Aspar Pharmaceutical

Smart Panel

System Overview

Download
2016_LUSAIL Multi Purpose Sports Arena_01_CTF_TR
Previous
Next

Product Highlights

Smart Panel provides solutions for damages which may occur as a result of panel crashing and friction particularly witnessed in transport sections of production facilities and also rusting problems particularly seen in facilities and slaughterhouses which are frequently washed with intensive chemicals.
 
1. Designed to withstand internal /external temperature differences of up to 80 degrees C
2. Internal temperature range of -50 degrees C to +60 degrees C
3. Incorporates a joint panel that achieves excellent thermal performance and can accomodate vapour and hygiene safe seals
4. Large range of profiles, coatings and inulation core thicknesss to meet project specific demands
5.  Available in lengths up to 11,75 metres
6.  Hygiene safe, resting moisture ingress and any risk of toxic mould and bacterial growth

 

Technical Information

Product Performance
Fire & Environmental Rating
Finishes & Coating
Downloads
Construction Details

Thermal Performance, Dimensions & Weight

The Kingspan KS110 CTF Coldstore system is supplied to construction projects complete with the unique Kingspan Camlock interlocking system
 
KS110CTF                  
Core thickness (mm) 45 60 80 100 120 140 150 170 200
U-Value (W/m2K) 0,44 0,33 0,25 0,2 0,17 0,14 0,13 0,12 0,10
R-Value (m2k/W) 2,27 3,03 4,00 5,00 5,88 7,14 7,69 8,33 10,00
U-Value (W/m2K) MegaCold 0,50 0,37 0,27 0,21 0,18 0,14 0,13 0,12 1,10
R-Value (m2k/W) MegaCold 2,00 2,70 3,70 4,76 5,56 7,14 7,69 8,33 0,91
Weight (kg/m2)
0,5 steel/0,5 steel
11,26 11,69 12,53 13,36 14,2 15,04 15,45 16,29 17,54

Performance Features

Heat Transmission
D = (λxΔt)/Q
D = Panel thickness (m)
λ = 0.020 W/mK,thermal conductivity of the panel
Δt = Difference between internal and external temperatures
Q = 10W/m2 design heat flow for refrigeration

Heat Transmision (W/m2) – Technical specification (Thermal conductivity factor for IPN core λ= 0,020 W/mk)
Recommended minimum insulation value for cold stores is 10 W/m2 heat gain
 

  Panel Thickness in mm
TemperatureDifference  45 60 80 100 120 140 150 170 200
20 ºC 8,90 6,67 5,00 4,00 3,33 2,86 2,67 2,35 2,00
25 ºC 11,11 8,33 6,25 5,00 4,17 3,57 3,33 2,94 2,50
30 ºC 13,33 10,00 7,50 6,00 5,00 4,29 4,00 3,53 3,00
35 ºC 15,56 11,67 8,75 7,00 5,83 5,00 4,67 4,12 3,50
40 ºC 17,78 13,33 10,00 8,00 6,67 5,71 5,33 4,71 4,00
45 ºC 20,00 15,00 11,25 9,00 7,50 6,43 6,00 5,29 4,50
50 ºC   16,67 12,50 10,00 8,33 7,14 6,67 5,88 5,00
55 ºC   18,33 13,75 11,00 9,17 7,86 7,33 6,47 5,50
60 ºC     15,00 12,00 10,00 8,57 8,00 7,06 6,00
65 ºC     16,25 13,00 10,83 9,29 8,67 7,65 6,50
70 ºC       14,00 11,67 10,00 9,33 8,24 7,00
75 ºC         12,50 10,71 10,00 8,82 7,50
80 ºC         13,33 11,43 10,67 9,41 8,00
85 ºC         14,17 12,14 11,33 10,00 8,50
90 ºC             12,00 10,59 9,00
95 ºC             12,67 11,18 9,50
100 ºC             13,33 11,76 10,00
Environmental Rating
Zero Ozone Depleting Potential (ODP), Low Global Warming Potential (GWP), Free From CFC, HCFC and HFC, Free from Halogentated Fire Retardents, 100% Recyclable

Not All Insulation is the Same

Fire Test Certification and Real Fire Case Studies

Coatings Brochure

External finishes and Colours Chart

Documents

MEATCA Building Envelope Product Portfolio

The Kingspan guide to our range of solutions across Roof & Wall, Cold Storage Systems, Facade & Rainscreen, Lighting, Clean Rooms and Structural products

Smart Panels Brochure

Learn more about Smart Panels

Not All Insulation is the Same

Fire Test Certification and Real Fire Case Studies

Certificates

Cold Storage Systems Fire Resistance Certificate KS110CTF - 13501 - 1

Turkish Standards Institution (TSE)

Cold Storage Systems Fire Resistance Certificate KS110CTF - 13501 - 2

Turkish Standards Institution (TSE)

TÜRKAK Registration Certification

Registration certification from TURKAK ISO 9001 for Insulated Panels

Certificate of Conformity to Turkish Standards (TSE)

Quality certificate from TSE

Certificate of Inspection

Factory production control inspection certificate - Turkey

FM 4880 Approved Certificate

Compliance certification is from FM for Wall Panel KS103 SSF & KS110CTF & KS103SSF thickness range 40-200 mm

FM 4881 Approved Certificate for KS103SSF, KS103MSF and KS110CTF

FM 4881 Approved certification from FM for Wall Panels

OHSAS 18001 Certification

Occupational Health and Safety certification is from OHSAS 18001

ISO 9001 Dakks

Quality certification from DakkS-ISO

LPCB Certificate of Product Approval

Registration certification is from LPCB 18001

Our technical team will support you with construction details for your project.

You may also be interested in...

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click "Accept and close" to accept the use of cookies on our website. If you do not click "Accept and close" but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.

The Cookie Policy & Control and Website Privacy Notice were updated on 13 August 2018.