More
Share
Twitter
Facebook
LinkedIn
x
Menu
Search
Products
Access Floors
Architectural Façade Systems
Architectural Roofing
Cleanrooms
Cold Storage Systems
Data Centre Solutions
Diesel, AdBlue & Agri Tanks
Ductwork
Insulated Panel Systems
Insulation
Structural Steel Products
Telemetry
Wastewater Management
Access Floors
Product Groups
Recent Products
Knowledge Base
Case Studies
Resources
Fire Safety
Back
Fire Safety
Fire Safety Overview
Reaction to Fire
Fire Spread
Flashover
Fire Resistance
Fire Safety Regulations
Help and Support
About Kingspan
Back
About Kingspan
About Kingspan Overview
Sustainable Buildings
News
Globe Icon
Central & Southern Asia, Middle East & Africa
Kingspan Group
Europe & Northern Asia
Albania (Shqipëri)
Andorra
Austria (Österreich)
Belarus (Беларусь)
Belgium (Belgique)
Belgium (België)
Bosnia & Herzegovina (Bosna i Hercegovina)
Bulgaria (България)
Channel Islands
Croatia (Hrvatska)
Cyprus (Κύπρος - EN / Kıbrıs - TÜ)
Czech Republic (Česká republika)
Denmark (Danmark)
Estonia (Eesti)
Faroe Islands (Færøerne Islands)
Suomi
France
Germany (Deutschland)
Gibraltar
Great Britain
Greece (Ελλάδα)
Hungary (Magyarország)
Iceland (Ísland)
Ireland
Italy (Italia)
Latvia (Latvija)
Liechtenstein
Lithuania (Lietuva)
Luxembourg
Macedonia (Македонија)
Malta
Moldova
Monaco
Montenegro (Црна Гора)
The Netherlands (Nederlands)
Northern Ireland
Norway (Norge)
Poland (Polska)
Portugal
Romania (România)
Russia (Россия)
San Marino
Serbia (Србија)
Slovakia (Slovensko)
Slovenia (Slovenija)
Spain (España)
Svalbard
Sverige
Switzerland (Schweiz)
Ukraine (Україна)
Vatican City (Città del Vaticano)
The Americas
Bermuda
Brazil (Brasil)
Canada
Cayman Islands
Colombia
Greenland (Grønland)
Mexico (México)
Puerto Rico
St Pierre & Miquelon
USA
US Virgin Islands
Rest of South & Central America (Resto de América del Sur y Central)
West Indies (Rest of)
Oceania
Australia
Melanesia
Micronesia
New Zealand
Polynesia
Middle East
Bahrain (البحرين)
Iraq (العـراق)
Israel (מְדִינַת יִשְׂרָאֵל)
Jordan (الأردن)
Kuwait (الكويت)
Lebanon (لبنان)
Oman (عُمان)
Qatar (قطر)
Saudi Arabia (المملكة العربية السعودية)
Syria (سوريا)
Turkey (Türkiye)
United Arab Emirates (لإمارات العربية المتحدة)
Yemen (اليَمَن)
East & South East Asia
East & South East Asia
South & Central Asia
Afghanistan (افغانستان)
Armenia (Hayastan)
Azerbaijan (Azərbaycan)
Bangladesh
Bhutan (druk gyal khap)
Georgia (Sakartvelo)
India
Kazakhstan (Қазақстан)
Kyrgystan (Кыргызстан)
Nepal (Nepāl)
Pakistan (Pākistān)
Sri Lanka
Tajikistan (Тоҷикистон)
Turkmenistan (Türkmenistan)
Uzbekistan (Oʻzbekiston)
Africa
Africa
Other Islands
Indian Ocean Islands
Southern Ocean Islands
South Atlantic Islands
x
English
Back
English
Türkçe
Français
Share Icon
Share
Search icon
Search
Close search bar icon
Submit search bar icon
Architectural Roofing
KingZip Linea
KingZip Infiniti
Structural Liners and Decks
Integrated Solutions
Finishes and Coatings
Book a Lunch and Learn CPD
Case Studies
Resources
Contact Us
KingZip Infiniti
Jump to:
Technical Details
Infiniti Grab
KingZip Infiniti
KingZip Infiniti offers you unprecedented freedom to create extraordinary 3D geometric buildings with complex shapes and forms - taking design and construction of the building envelope to new levels.
1. Kingzip Infinity can be tapered or smooth curved to 1m convex and 12m concave radii
2. Available in cover widths from 150mm to 800mm
3. Advanced structural, thermal, acoustic and fire performance
4. Exceptional long term weatherisation and durability
Technical Details
Product Detail
Halters
Acoustic
Testing Standards & Approvals
Construction Details
Weatherisation
Thermal Performance
NBS Spec
3D
KingZip SF
Product
specification
No
.
Product
Specification/Capability
1
Max/Min sheet cross section
Limits for rollformer: Wmax=
1000 mm (with container side open)
800 mm (with container side closed, need to use edge
trimmers)
Wmin=130 mm
Limits for curving machine: Wmax=1000 mm
Wmin= 190 mm
2
Min sheet tapering criteria
Limited by trimming action of 700mm max (350mm from each edge)
From 100 to 800 mm or
From 300 to 1000 mm
3
Max variable path angle
+/- 10 ° on short lengths
+/- 8 ° as average
4
Min/Max radii on variable width
Rmin = 10 to 20 mtrs, gauge and shape dependent
5
Rib path for varible width to follow seam path
Side mini ribs following standing seam path at a distance from 70 to 250 mm;
Center mini rib always following the centre of the profile, also the freeform profiles..
6
Sheet length tolerance
Tolerance +/-0,5% on length
7
Max/Min sheet
concave
radii
Material: Aluminum, 2 mini ribs
Thickness
parallel
tapered
freeform
1,2
R=8000
R=8000
R=8000
1,0
R=10000
R=10000
R=10000
0,9
R=15000
R=15000
R=15000
It is required to process the profile performing through progressive passes through the curving machine to get final curved shape, particularly when target radius is tight.
Subject to complexity of shape and sheet 3d curve radius required
8
Max/Min sheet
convex
radii?
Thickness
parallel
tapered
freeform
1,2
R=1000
R=1000
R=1000
1.0
R=1200
R=1200
R=1200
0,9
R=1800
R=1800
R=1800
Material: Aluminum
It is required to process the profile performing through progressive passes through the curving machine to get final curved shape, particularly when target radius is tight
Subject to complexity of shape and sheet 3d curve radius required
9
Min sheet length
2750 mm
10
Max taper width
Wmax=
1000 mm (with container side open)
800 mm (with container side closed, need to use edge trimmers)
11
Min taper width
Wmin=130 mm for uncurved panels
Wmin=190 mm for curved panels
12
Aluminium material gauges
Aluminium 0.7 to 1.2mm
Aluminium Halters
Our extruded aluminium halters are supplied complete with pre-fitted thermal pads.
Thermal Halters
Our polyamide "thermohalters" provide enhanced thermal and acoustic system performance, mitigating thermal bridging through the roof assembly
Acoustic performance is a key requirement on many projects, especially public use buildings. Kingzip Linea has the flexibility to meet the acoustic performance specifications for any building.
Acoustic Board - Gypsum Board 720kg/m3 density
Cement Board - 1,250 kg/m3 density or specific high density rubber mat
Sound Reduction - Rw values from 36dB to 50dB
Sound absorbtion - NRC values from 0.5 to 0.85 for our standard perforation patterns. Project specific NRC values on request.
Fire Performance
Kingzip Linea achieves a class 0 rating as defined in various national building regulations. These systems are classed as non - combustible.
Test
Result
BS 476-3:2004 Classification and method of test for external fire exposure to roofs
FAA/SAA
BS 476-6:2009 Method of test for fire propagation for products
1< 12 i < 6
BS 476-7:1997 Method of test to determine the classification of the surface spread of flame of products
Class 1 rating for aluminium/steel inner/outer metal facings
FM 4471 Panel Roofs
Class 1A
Our Kingzip roof systems are manufactured and supplied under:-
ISO14001:2004
BS EN ISO 9001
Compliant with ASTM E1637
Systems with UL 580-90 certification are available
KingZip Freeform Building Envelope Solutions Construction Details
Standing Seam Systems
Download
Download
Kingzip Infinity provides proven exceptional weatherisation performance, with aluminium options being the preferred choice for highly demanding environments such as airports , marine, industrial and urban locations.
Kingzip Infinity has been subjected to CWCT and ASTM E1680 and achieves 5m3/hr/m2 50pa.
KingZip Standing Seam Sytems NBS Spec
Roofing system
Download
Download
Bring Art and Architecture together with KingZip:
- make your vision a reality
- create stunning aesthetitcs
- be free to design extraordinary buildings
KingZip Infiniti offers unparalleled architectural and technical performance capability combined with a range of finishes and materials.
Our unlimited manufacturing capability of KingZip Infiniti enables you to realise distinctive buildings that showcase creative and artistic vision on a global stage.
Infiniti is manufactured on the construction site using mobile facilities that can be deployed anywhere in the world.
Contact us for bespoke specifications for your project ...
Contact Us