Kingspan Day-Lite Kapture

Diffusion: 100%

UV resistant: 100%

Material: Triple-glazed polycarbonate maximises both light transmission and diffusion

U-value: 2.2 W/m2K (glazing)

Features:
  • The unique shape captures the optimal level of light
  • The rooflight utilizes nano-prismatic technology which eliminates glare and hot spots, reducing heat gains in buildings

Kingspan Day-Lite Kapture - Technical Information

Documents
Product Information
Guarantee
BIM
DoP
CE
CAD.DWG
CAD.PDF

Kingspan Day-Lite Kapture - Product Data Sheet

Kingspan Day-Lite Kapture - Order Form

Kingspan Day-Lite Kapture - Installation Instructions

Kingspan Day-Lite Kapture - Kerb Assembly

Kingspan Day-Lite Kapture - Safety Screen Installation Instructions

Dimensions and Weights
  Kerb O.D. Kerb O.D. External Dimensions External Dimensions Daylight Opening Dimensions Daylight Opening Dimensions Daylight Opening Dimensions Weight*
  Length Width Length Width Length Width Area  
Product Reference (mm) (mm) (mm) (mm) (mm) (mm) (m2) (kg)
KS700DLK 780 780 810 810 692 692 0.4 12
KS1400DLK 780 1560 810 1590 692 1472 1.0 24
KS1500DLK 1630 1560 1660 1590 1542 1472 2.2 44
KS2750DLK 2845 1560 2875 1590 2757 1472 4.0 62
*To be confirmed. Weight does not include kerb or mesh.


 
Product Reference Diffusion SHGC (g-value) Light Transmission (%)**
Standard 100% 0.70 83
Climate Control 100% 0.45 81
**Light Transmission according to EN 410 is as measured on 600mm x 600mm samples


 
H&S Clasification & Fire Performance  
H&S Clasification Non-fragility to ACR [M]001: 2014 Class B, when installed as per Kingspan details
Non-fragility to BS EN 1873: 2014 Class SB1200 when installed as per Kingspan details
Fire Performance Day-Lite Kapture polycarbonate achieves European class B-s1-d0 to EN13501

 
Covered by a 25 year guarantee
Click here to access the BIM Store to download the BIM files for this premium rooflight

Kingspan Day-Lite Kapture Rooflight BIM Files 

Kingspan Day-Lite Kapture - Declaration of Performance

Kingspan Day-Lite Kapture - CE

Kingspan Day-Lite Kapture - KS700DLK Construction Details DWG

Kingspan Day-Lite Kapture - KS1400DLK Construction Details DWG

Kingspan Day-Lite Kapture - KS1500DLK Construction Details DWG

Kingspan Day-Lite Kapture - KS2750DLK Construction Details DWG

Kingspan Day-Lite Kapture - KS700DLK_150 RW Construction Details PDF

Kingspan Day-Lite Kapture - KS700DLK_309 RW Construction Details PDF

Kingspan Day-Lite Kapture - KS700DLK_309 RW with Aluminium Soaker Construction Details PDF

Kingspan Day-Lite Kapture - KS700DLK_150 Topdek Construction Details PDF

Kingspan Day-Lite Kapture - KS700DLK_309 Topdek Construction Details PDF

Kingspan Day-Lite Kapture - KS1400DLK_150 RW Construction Details PDF

Kingspan Day-Lite Kapture - KS1400DLK_309 RW Construction Details PDF

Kingspan Day-Lite Kapture - KS1400DLK_309 RW with Aluminium Soaker Construction Details PDF

Kingspan Day-Lite Kapture - KS1400DLK_150 Topdek Construction Details PDF

Kingspan Day-Lite Kapture - KS1400DLK_309 Topdek Construction Details PDF

Kingspan Day-Lite Kapture - KS1500DLK_150 RW Construction Details PDF

Kingspan Day-Lite Kapture - KS1500DLK_309 RW Construction Details PDF

Kingspan Day-Lite Kapture - KS1500DLK_309 RW with Aluminium Soaker Construction Details PDF

Kingspan Day-Lite Kapture - KS1500DLK_150 Topdek Construction Details PDF

Kingspan Day-Lite Kapture - KS1500DLK_309 Topdek Construction Details PDF

Kingspan Day-Lite Kapture - KS2750DLK_150 RW Construction Details PDF

Kingspan Day-Lite Kapture - KS2750DLK_309 RW Construction Details PDF

Kingspan Day-Lite Kapture - KS2750DLK_309 Topdek Construction Details PDF

Kingspan_Katpure_Air_3D_Render_Ireland

Kingspan Day-Lite Kapture Air

Diffusion: 100%

Material: This vented rooflight is triple-glazed using specially designed polycarbonate layers

 U-value: 1.3 W/m2K (base) and 2.2 W/m2K (glazing)

Features:
  • With a motorised actuator for ventilation, as well as exploiting natural daylight
  • Quick & easy installation and can be installed on roofs with pitches up to 25o
  

Kingspan Day-Lite Kapture Air - Technical Information

Documents
Product Information
Guarantee
BIM

Kingspan Day-Lite Kapture Air - Product Data Sheet

Dimensions
Product Reference Roof Opening
Length x Width (mm)
Skylight Base Interior
Length x Width (mm)
Drive
Lift Height (mm)
Free Ventilation Area
(m2)
KS700DLK 930 x 930 730 x 730 300 0.44
KS700DLK 930 x 930 730 x 730 500 0.73
KS1400DLK 1720 x 930 1520 x 730 300 0.68
KS1400DLK 1720 x 930 1520 x 730 500 1.13
KS1500DLK 1720 x 1790 1520 x 1590 300 0.93
KS1500DLK 1720 x 1790 1520 x 1590 500 1.56
KS2750DLK 1720 x 2996 1520 x 2796 300 1.29
KS2750DLK 1720 x 2996 1520 x 2796 500 2.16
 

 
Product Reference Diffusion SHGC (g-value) Light Transmittance (%)*
Standard 100% 0.70 83
Climate Control 100% 0.45 81
*Light transmission according to EN 410 is as measured on 600mm x 600mm samples


 
H&S Classification and Fire Performance  
H&S Classification Non-fragility to ACR [M]001: 2014 Class B, when installed as per Kingspan details
Non-fragility to BS EN 1873: 2014 Class SB1200 when installed as per Kingspan details
Fire Performance Day-Lite Kapture polycarbonate achieves European class B-s1-d0 to EN13501
Covered by a 25 year guarantee.
Pneumatic and electrical actuators for Smoke and Heat Exhaust Ventilation are covered by a one year warranty, which can be extended with a Service and Maintenance contract.
Click here to access the BIM Store to download the BIM files for this vented rooflight

Kingspan Day-Lite Kapture Air BIM Files
Kingspan_Kapture_Smoke_Vent_Open_3D_Render_Ireland

Kingspan Day-Lite Kapture Smoke Vent

Diffusion: 100%

Material: The rooflight is triple-glazed with polycarbonate.

U-value: 1.3 W/m2K (base) and 2.2 W/m2K (glazing)

 Features:
  • With a thermal-pneumatic opening mechanism, this natural smoke and heat extraction system opens to 165o
  • The opening mechanism is automatically triggered at 68o, or can be manually opened at emergency triggering stations
  • Can be installed on roof pitches up to 25o

Kingspan Day-Lite Kapture Smoke Vent - Technical Information

Documents
Product Information
Guarantee
BIM

Kingspan Day-Lite Kapture Smoke Vent - Product Data Sheet

Dimensions and Performance
Product Reference Roof Opening
Length x Width (mm)
Skylight Base Interior
Length x Width (mm)
Aa value with
Wind Detectors (m2
Aa value without
Wind Detectors (m2)
KS1500DLK-SV 1720 x 1790 1520 x 1590 2.15 1.85
KS2750DLK-SV 1720 x 2996 1520 x 2796 3.35 2.32
 

 
Product Reference Diffusion SHGC (g-value) Light Transmittance (%)*
Standard 100% 0.70 83
Climate Control 100% 0.45 81
*Light transmission according to EN 410 is as measured on 600mm x 600mm samples


 
H&S Classification and Fire Performance  
H&S Classification Non-fragility to ACR [M]001: 2014 Class B, when installed as per Kingspan details
Non-fragility to BS EN 1873: 2014 Class SB1200, when installed as per Kingspan details
Fire Performance Day-Lite Kapture polycarbonate achieves European class B-s1-d0 to EN13501
Base achieves B2 according to DIN 4102-1 and E according to DIN EN 13501-1
Pneumatic opener mechanism achieves DIN EN 12101-2
Covered by a 25 year guarantee.
Pneumatic and electrical actuators for Smoke and Heat Exhaust Ventilation are covered by a one year warranty, which can be extended with a Service and Maintenance contract.
Click here to access the BIM Store to download the BIM files for this natural smoke and heat extraction rooflight

Kingspan Day-Lite Kapture Smoke Vent BIM Files

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click "Accept and close" to accept the use of cookies on our website. If you do not click "Accept and close" but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.

The Cookie Policy & Control and Website Privacy Notice were updated on 13 August 2018.