KS1000 TD Membrane Roof

Topdek is a single component, factory pre-engineered roof deck, comprising a high performance single-ply PVC / TPE membrane with insulation and a trapezoidal steel deck. 

2016_THE HUT GROUP LOGISTICS CENTRE_WARRINGTON_02_AWP MR TW_UK.jpg

KS1000 TD

Profiles: Flat single-ply PVC / TPE membrane, with optional standing seam aesthetic
Fixing detail: Secret-fix appearance
Metal type: N/A
Colours: PVC / TPE Membranes. Download a copy of the coating selector here
Application: Membranes
Lengths: Flat and pitched roofs above 1:80 (0.72°) after deflection
Cover width: 1000mm
Fire rating: Please see the fire tab below within the techical information section or contact our technical services team for more information on the fire rating for this product. Visit our comprehensive Fire Safety area for information on how our tested and accredited systems meet Compliance and Insurance Industry Approval and perform in real fire case studies.
Product compatibility: Integrates with Kingspan Safety Solutions and Kingspan Roof Mounted PV System
 

Dimensions, Weight & Thermal Performance

Core Thickness (mm) 34 71 91 100 120
Overall Thickness (mm) 72 109 129 138 158
U-Value (W/M²K) 0.48 0.25 0.20 0.18 0.15
Weight kg/m² 0.5mm Deck 9.0 10.5 11.3 11.7 12.5

Looking for a sample?
Please contact

2016_THE HUT GROUP LOGISTICS CENTRE_WARRINGTON_02_AWP MR TW_UK.jpg

System Accessories & Services

For 50 years, Kingspan insulated panel technology has led the industry in thermal-efficiency, fire safety and lifetime durability.

Today, Kingspan also offers enormous aesthetic flexibility with a vast range of insulated panel profiles supported by state-of-the-art specialist fabrications. Together with advanced daylighting and integrated rooftop solar PV, this enables Kingspan to deliver the complete envelope solution.

Build Speed

Topdek reduces costly roofing delays by installing your steel deck, insulation core and weather membrane in a single operation. This means buildings become weathertight faster and installers spend less time on the roof helping improve safety and manage project costs.

Looking for a quotation or technical advice for your project? Request a call back....

Get in touch today and we'll aim to contact you within 24 hours.


I consent to the terms of the Website Privacy Notice
2011_ASHFORD BUILD PROGRESS_ASHFORD_05_BC_UK.jpg

Projects

Technical Information

Installation Guides
CAD Details
Product Data Sheet
Fire
BIM
NBS

Kingspan Topdek Installation Guide

Kingspan TopDek CAD DWG

Kingspan TopDek CAD PDF

Kingspan TopDek DataSheet


Fire
 
The external and internal faces of the panel to be Class 0 in accordance with the Building Regulations when tested to BS 476: Part 6: 2009 and Part 7: 1997. The panel is rated FAA or FAC (depending on membrane used) when tested to BS 476: Part 3: 2004.
This FIREsafe system has passed all the requirements of LPS 1181: 2005: Part 1: Issue 3, ceiling lining tests by the Loss Prevention Certification Board (LPCB) certified to LPS 1181 Grade EXT – B and FM approval to FMRS 4471.
 
Environmental
 
This ECOsafe system may achieve a Green Guide A+ rating and is subject to project specific assessments.
 

BIM Store

Click here to visit the BIM Store to download the BIM files for this product.

BIM Store

Education and Training

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click "Accept and close" to accept the use of cookies on our website. If you do not click "Accept and close" but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.

The Cookie Policy & Control and Website Privacy Notice were updated on 13 August 2018.