Membrane Lined Insulated Gutter

Kingspan Insulated Panel Systems Insulated Gutters Image

Product Overview

  • U-Value: 0.67W/m2k (30mm think) to 0.21W/m2k (100mm thick)
  • Membrane: IKO Armourplan (0.6mm and1.2mm) and Sika-Trocal (0.8 and 1.2 mm)
  • Application: Boundary, valley and valley-hip
  • Lengths: Available in lengths up to 8m
  • Fire Rating: LPCB certified to LPS 1181 Grade EXT-B
  • Non-Fragility Performance: Achieves ACR[M]001: 2014 Class B (maximum 868mm boundary sole, 700mm valley sole dimension)
  •  Product Compatibility: Most Kingspan Insulated Roof Panels
  • Warranty: Guaranteed structural, thermal and fire performance for up to 25 years
The only LPCB certified insulated gutter system available on the market. The system is lightweight and available in up to 8m lengths for quick installation. 
Kingspan Insulated Panel Systems Membrane Lined Insulated Gutter Brochure Image

Download the Brochure

Download our insulated gutter guide to learn more about our gutter composition, access typical construction details and available ancillaries and see how our technical services can support you.

Technical Information

Installation Guides
CAD Details
Product Data Sheet
Fire
NBS

Kingspan Membrane Lined Insulated Gutter Installation Guide

Kingspan Membrane Lined Insulated Gutter Boundary Wall CAD DWG

Kingspan Membrane Lined Insulated Gutter Boundary Wall CAD PDF

Kingspan Membrane Lined Insulated Gutter Parapet CAD DWG

Kingspan Membrane Lined Insulated Gutter Parapet CAD PDF

Kingspan Membrane Lined Insulated Gutter Valley CAD DWG

Kingspan Membrane Lined Insulated Gutter Valley CAD PDF

Kingspan Membrane Lined Insulated Gutter DataSheet

This FIREsafe system has passed all the requirements of LPS 1181: 2005: Part 1: Issue 1.1, ceiling lining tests by the Loss Prevention Certification Board (LPCB) certified to LPS 1181 Grade EXT – B

For more information on fire performance please contact the Kingspan Technical Services Department. 

 

Kingspan Membrane Lined Insulated Gutter NBS

Dimensions, Weight and Performance

Core Thickness (mm) 30 40 50 60 70 80 100
Weight (kg/m2) (0.6mm outer / 0.5mm liner) * 11.4 11.8 12.2 12.6 12.9 13.3 14.2
U-value (W/m2k)** 0.67 0.51 0.41 0.35 0.30 0.26 0.21

*Based on 1m2 of top sheet, insultion and liner. 
**The U-value has been calculated using the method required by the appropriate National Building Regulations. 
We have a number of factory-fitted outlets available on request. These items are available PVC dipped to ensure that installation on site is as simple as possible. Outlets include;
 
  • Weir Chutes
  • Hopper Boxes 
  • Sumps
  • Tapered Outlets
  • Tell-tales 
  • Overflows 
  • Syphonic Outlet (customer own supply)

Looking for a sample?
Please contact

Kingspan Insulated Panel Systems Insulated Gutters Wirtgen AU Image

Complete Systems & Services

For 50 years, Kingspan insulated panel technology has led the industry in thermal-efficiency, fire safety and lifetime durability.

Today, Kingspan also offers enormous aesthetic flexibility with a vast range of insulated panel profiles supported by state-of-the-art specialist fabrications. Together with advanced daylighting and integrated rooftop solar PV, this enables Kingspan to deliver the complete envelope solution.

Projects

We're here if you need
more technical advice

Education & Training

Contact Us

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click "Accept and close" to accept the use of cookies on our website. If you do not click "Accept and close" but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.

The Cookie Policy & Control and Website Privacy Notice were updated on 13 August 2018.