Aspar_UK_CaseStudy_Cleanrooms_ Versatile_Wall. (10)

UltraTech Versatile
Wall & Ceiling Panel

The UltraTech Versatile wall and ceiling panel has been designed for semi-flush cleanroom environments. Choose from a range of insulation cores, widths and heights.
Download
Aspar_UK_CaseStudy_Cleanrooms_ Versatile_Wall. (1)
Previous
Next

Product Highlights

Fixing detail: Semi flush
Metal type: Continuously hot-dip coated strip and sheet of structural steel
Core types: QuadCore, ECOsafe PIR, MF core
Lengths:  Check specific core for available lengths
Thickness : A range of thicknesses from 40-100mm. Check technical details of specific core for list of availabel thicknesses
Fire rating: Refer to technical datasheet for specific core performance
Air Leakage:
Product compatibility: Integrates with the entire UltraTech Versatile system
Coatings: Kingspan CLEANsafe and HYGIENEsafe coatings
 
StJames_Dublin_CaseStudy_Cleanrooms_IRL_20

Compatible with:
De-Ended Panel

UltraTech Versatile de-ended panel, with folded panel ends, allows for  flush integration with a range of cleanroom accessories.
  • Quadcore, ECOsafe PIR cores
  • UltraTech Versatile panels are available with de-ending to both top and bottom of the panel.
  • Allows for flush integration into our adjustable floor track.

Coatings

Coating name CLEANsafe 15 CLEANsafe 25 CLEANsafe 55 HYGIENEsafe CLEANsafe 316
Coating type Polyester 15µm Polyester 25µm PETfilm 55µm PVC rigid film : 120µm Mill finish stainless steel – grade 316
Nominal thickness 0.6mm/ 0.2in (incl coating) 0.6mm/ 0.2in (incl coating) 0.6mm/ 0.2in (incl coating) 0.6mm/ 0.2in (incl coating) 0.6mm/ 0.2in
Protection film No Yes (standard) Yes (standard) Yes (standard) Yes (standard)

System Services & Accessories

Our dedicated technical support team will be on hand at each stage of the cleanroom cycle;
pre- and post manufacture.

Contact us for complimentary services including: guidance around ISO classifications for cleanrooms, TEKLA modelling, advice on fire & acoustic performance,U Value calculations,  bespoke construction detail,  ceiling panel load spans, structural calculations, optimised building energy modelling, factory tours and field services. 
 
UltraTech Cleanroom Assembly_windows walls doors windows

Explore other components in the UltraTech Versatile System

Case Studies

Client Testimonials

We spoke to Sonaca Aerospace about their UltraTech Versatile cleanroom; made possible with our long panel spans and QuadCore microcell core.
 
StJames_Dublin_CaseStudy_Cleanrooms_IRL_15 - Copy

Global Case Study Book

Our brand new global case study book is now available to download, featuring projects from around the globe. Click here to download.

Technical Information

Product Data Sheet
UltraTech Versatile De-Ended Panel
ECOsafe PIR
Coatings
MF Core
QuadCore

UltraTech De-Ended Panel

Kingspan UltraTech Versatile 1100mm panels have a unique 
de-ended panel solution, available for 60mm & 80mm thickness panels only. This allows for fully flush integration with a range of cleanroom accessories.

The panel core, Quadcore, ECOsafe PIR or MF is factory routered from the bottom of the Versatile wall panels. Extruded Aluminium top hat profile is placed into the de-ended panel with the panel face folded around. Patent pending.

UltraTech Versatile panels are available with de-ending to both 
top and bottom of the panel. This unique detail allows for flush integration into our adjustable floor track.
 

Applications

UltraTech Precision ECOsafe PIR panels are suitable for all internal cleanroom applications including new build and refurbishment projects across a varietly of sectors, including pharmaceutical and bio-technology laboratories; healthcare; medical research and advanced technology facilities.


Dimensions, Weight & Performance
Overall Thickness 60mm, 80mm
Standard Width 300, 600, 900 and 1200mm
Length** 300-5700mm
Weight (0.63 / 0.63 steel) 18kg/m2**
Thermal Conductivity 0.019 W/mK**
* Variable widths available in 10mm increments. Minimum width 150mm.
**Based on 80mm precision panel thickness.

Product Tolerances
Length + 1.5mm - 1.5mm
Width + 1.5mm - 1.5mm
Thickness + 2.0mm - 2.0mm
Flatness (per metre) + 0.5mm - 0.5mm
End Sqaureness + 2.0mm - 2.0mm

Fire Performance
Surface Spread of Flame: The steel outer and inner facings have Class 1 surface spread of flame to BS 476-1: 1997 (Fire tests on building materials and structures. Method of test to determine the classification of the surface spread of flame of products) and are Class 0, as defined by Building Regulations. Reaction to fire B.S2,d0 according to EN13501.

Acoustic Performance
UltraTech Precision ECOsafe PIR panels have a predicted single figure weighted sound reduction Rw = 24dB.

Sound Reduction Index (SRI
Frequency (Hz) SRI (dB)
63 20
125 15
250 17
500 23
1000 18
2000 25
4000 40 
8000 46


Insulation Core
UltraTech Precision ECOsafe PIR panels feature an environmentally sustainable closed-cell PIR insulation core which is non-deleterious with Zero Ozone Depletion Potential (Zero ODP).

Biological
UltraTech Precision ECOsafe PIR panels are resistant to attack from mould, fungi, mildew and vermin. No urea formaldehyde is used in the manufacture of the panels. UltraTech Precision ECOsafe PIR panels can incorporate project-specific HYGIENEsafe, wash and clean down facings. 

Panel Joint
UltraTech Precision ECOsafe PIR panels feature a unique aluminium perimeter profile on all sides to create a fully flush joint. The panel side joint can accommodate a hygienic silicone seal finish. The joint created between the wall panels also allows for concealment of services. 

Airtightness 
UltraTech Precision MF Core panels  achieve airtightness of less than 0.003m3/hr/m2 at 50Pa in accordance with EN 14509

Watertightness
UltraTech Precision ECOsafe PIR panels are watertight to 1050Pa (Class B) according to EN 14509.
Please contact Kingspan Technical for further details on panel coating compatibility with H2o2 and other chemicals.

Kingspan CLEANsafe 15
Kingspan CLEANsafe 15 is a basic polyester coating suitable for standard internal environments, providing reasonable chemical and humidity corrosion resistance.
  • Polyester coating: 15µm
  • Nominal thickness: 0.63mm (incl. coating)
  •  Protection film: No
Kingspan CLEANsafe 25
Kingspan CLEANsafe 25 is a polyester coating suitable for moderately aggressive internal environments, providing good chemical and humidity corrosion resistance.
  •  Polyester coating: 25µm
  • Nominal thickness: 0.63mm (incl. coating)
  • Protection film: Yes (standard)

Kingspan CLEANsafe 55
Kingspan CLEANsafe 55 is a chemically inert colaminated polyethylene terephthalate (PET) film and polyester (PE) paint, applied to pre-treated metal, suitable for humid and chemically aggressive internal environments.
  • PET film: 55µm
  •  Nominal thickness: 0.63mm (incl. coating)
  • Protection film: Yes (standard)

Kingspan HYGIENEsafe
Kingspan HYGIENEsafe is our unique chemically inert, 
anti-bacterial coating. A rigid polyvinylchloride (PVC) phthalate-free coating applied to pre-treated metal and suitable for humid and chemically aggressive internal environments.
  •  PVC Rigid film: 120µm
  • Nominal thickness: 0.63mm (incl. coating)
  • Protection film: Yes (standard) 
Kingspan CLEANsafe 316
CLEANsafe 316 is cold rolled annealed austenitic stainless steel, suitable for corrosive internal environments.
  •  Mill finish stainless steel – grade 316
  •  Finish 2B
  •  Nominal thickness: 0.63mm 
  •  Protection film: Yes (standard)

Colour Range

RAL 9010* and RAL 9002*
*Nearest match, samples available on request.
Other colours available on request.
 

Applications

The UltraTech Versatile MF panels are designed for cleanroom environments where fire safety is important. The panels are suitable for all internal Cleanroom applications including new build and refurbishment projects. The UltraTech Versatile mineral fibre panels are typically installed vertically, also suitable for Horizontally installed applications.


Dimensions, Weight & Performance
Overall Thickness 60, 80, 100, 120, 150, 170, 200, 240, 300mm
Standard Width 1170mm
Length** 1.2m-19.2m
* 1120mm cover width available for container transport.
**Panel lengths 13.5m-19.2m subject to additional transport charge.

Product Tolerances
Length + 1.5mm - 1.5mm
Width + 2.0mm - 2.0mm
Thickness + 2.0mm - 2.0mm
Flatness (per metre) + 1.0mm - 1.0mm
End Sqaureness + 2.0mm - 2.0mm


MF 50C: λ = 0.041 W/m.K
Core Thickness (mm) 60 80 100 120 150 170 200 240 300
Weight (0.6 / 0.5) (kg/m2) 14.93 16.83 18.73 20.63 23.48 25.38 28.23 32.03 37.63
U-value (W/m2K) 0.62 0.48 0.39 0.33 0.26 0.23 0.20 0.17 0.13

MF 50F: λ = 0.044 W/m.K​
Core Thickness (mm) 60 80 100 120 150 170 200 240 300
Weight (0.6 / 0.5) (kg/m2) 16.43 18.83 21.23 27.23 23.48 29.63 32.33 38.03 45.23
U-value (W/m2K) 0.67 0.51 0.41 0.35 0.28 0.25 0.21 0.18 0.14


Insulation
UltraTech Versatile MF panels feature a mineral wool insulation core, 50C and 50F, consisting of vertically-oriented fibres. As a result of this orientation, the panels provide excellent mechanical properties (high tensile and compression strength).

Density
The nominal density is as below:
  • 50C = 95kg/m3.
  • 50F = 120kg/m3.
Fire Performance
  •  Reaction to fire: A2-S1,d0 according to EN 13501.
  • FM approval standard 4880 (2005).

Applications

UltraTech Versatile QuadCore panels are designed for all internal cleanroom applications including new build and refurbishment projects.


Dimensions, Weight & Performance
Overall Thickness 80mm*
Lengths 1.2m - 19.5m
Cover Width** 1100mm
Weight (0.63 / 0.63 steel) 14.06kg/m2
Thermal Conductivity 0.018 W/mK
*Fully flush finish only available with 80mm thick panel.
**Other specific widths available on request.

Product Tolerances
Length + 4.0mm - 4.0mm
Width + 2.0mm - 2.0mm
Thickness + 2.0mm - 2.0mm
Flatness (per metre) + 1.0mm - 1.0mm
End Sqaureness + 2.0mm - 2.0mm


 
Core Thickness (mm) 50 60 80 100 125 150 175 200 220
Weight (0.63 / 0.63) (kg/m2) 12.86 13.26 14.06 14.86 15.86 16.86 17.86 18.86 19.66
U-value (W/m2K) 0.38 0.31 0.23 0.18 0.15 0.12 0.10 0.09 0.08
Notes: These values are in accordance with BS EN 14509, using Finite Element Analysis, and take into account any thermal bridging through the longitudinal joint. The U-values have been calculated using an aged thermal conductivity value of 0.018W/mK.

Fire Performance
The external and internal faces of the panel to be Class 0 in accordance with the Building Regulations when tested to BS 476: Part 6: 2009 and Part 7: 1997.
UltraTech Versatile panels with Quadcore have passed all the requirements of:
  • FM 4882 for smoke sensitive occupancies: Class 1 for interior walls and ceiling. (With no height restriction).
  •  LPS 1181: 2014: Part 1: Issue 1.2, series of fire growth tests for LPCB approval and is certified to LPS 1181 Grade EXT-B.*
  •  LPS 1181: 2005: Part 2: Issue 2.0, series of fire growth tests for LPCB approval and listing of construction product systems to LPS INT-3*, INT-2.*
  • LPS 1208: 2014: Issue 2.2, LPCB fire resistance requirements for elements of construction used to provide compartmentation providing: FR30 & FR60 – Wall & Ceiling, specifications are available on request.
  •  FM approval to FMRC 4880, 4881 Class 1 fire classification, 
    unlimited height.**
  • Reaction to fire classification according to BS EN 13501-1: 2007 + A1: 2009: B-s1,d0.


 

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click "Accept and close" to accept the use of cookies on our website. If you do not click "Accept and close" but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.

The Cookie Policy & Control and Website Privacy Notice were updated on 13 August 2018.