Architectural Facade Systems

QC_Karrier_-_DD_Direct_Finish_2019

Dri-Design on QuadCore® Karrier

Tested Build-up
 
  • 32mm deep mill finished aluminium cassettes installed onto outer face of QuadCore® Karrier panel
  • 80mm thick Hybrid insulated QuadCore® Karrier panel
  • 12.5mm plasterboard lining on 100mm deep Kingspan Kingframe SFS

Test Report BS 8414-2: 2015 - P107922-1000 Download here
Classification Report BR 135: 2013 Annex B - P107922-1001 Download here
DD - K_Slab Fire Test BS 8414

Dri-Design with K-Roc Rainscreen Slab

Tested Build-up 
 
  • Dri-Design aluminium cassette of 2mm thickness, of PPC dark copper colour as finishing on the outer face
  • Air cavity 38mm thick, measured between insulation and Omega profiles
  • Siderise RV 90/30 (Siderise) Vertical open state cavity barrieSiderise RH25G 90/30 (Siderise)
  • Horizontal open state cavity barrier 
  • Two layers of Kingpsan K-Roc Rainscreen slab insulation of 100mm thickness
  • Breather membrane TYVEK FireCurb (DuPont) Sheathing board Y-wall (RCM) of 12mm thickness 
  • Earthwool Omni fit slab insulation (KNAUF) of 100mm thickness fitted in between the stufSteel frame system of steel 'C' sections with 100mm x 50mm studs 
  • Air and vapour control layer of Airguard control membrane (DuPont)
  • Two layers of 15mm Knauf Wallboard (GYPROC Saint-Gobbain
Test Report BS 8414-2:2015+A1:2017 - EUI - 18 - FF - 000081A Download Here
Classification Report BR 135 third edition 2013 - EUI-18-000081A Download Here
QC Karrier Hook-On Cassette Full System Fire Test

Metallic Hook-on Cassette

Tested Build-up
 
  • 60mm deep mill finshed aluminium cassettes installed on vertical supports
  • 85mm cavity formed with vertical extruded aluminium supports installed on to outer face of 100mm thick PIR insulated Wall Liner panel
  • 12.5mm plasterboard lining on 100mm deep SFS

Test Report BS 8414-2: 2005 - 297804 Download here
Classification Report BR 135: 2013 Annex B - 299571 Download here
Corium Brick Tile BRE Fire Resting Full System Fire Test

Corium Brick Tile

Tested Build-up
  • 35mm Corium brick tile on coated steel rails
  • Vertical 50mm deep top-hats at 275mm centres installed on to outer face of 220mm thick Hybrid insulated Wall Liner panel
  • No lining. Cold formed steel angles to edge of floor slab

Test Report BS 8414-2: 2005 - P102340-1000 Download here
Classification Report BR 135: 2013 Annex B - P102340-1002 Download here
 
QuadCore Evolution Axis BRE System Fire Testing

QuadCore® Evolution

Tested Build-Up 
 
  • 100mm thick QuadCore® Evolution panel 
  • Siderise RH2HG 90/30 (Siderise) Horizontal open state cavity barrier 
  • Earthwool Omni fit slab insulation (KNAUF) of 100mm thickness fitted in between the studs
  • Steel frame system of steel 'C' sections with 100mm x 50mm studs
  • Air and vapour control layer of Airguard control membrane (DuPont) 
  • Two layers of 15mm Knauf Wallboard (GYPROC Saint-Gobbain)

Test Report BS 8414-2:2015 - EUI - 18 - FF – 000081B Download here
Classification Report BR135: 2013 Annex B - EUI-18-000081B Download here
Fire Safety Evolution Panelised Facade Full System Fire Test 2019

Evolution

Tested Build-up
 
  • 150mm thick PIR Insulated Evolution panel
  • No lining. Vertical hot rolled hollow sections

Test Report BS 8414-2:2005 - 293939 Download here
Classification Report BR135:2013 Annex B - 289585 Download here

Insulation

K15 pigeon grey 140mm insulation v2

Tested Build-up:

  • 30mm Taylor Maxwell Tampa terracotta tiles fixed to an aluminium vertical support railing system
  • Aluminium top hat support
  • Aluminium helping hand bracket
  • AIM horizontal cavity barrier with intumescent strip
  • 140mm Kingspan Kooltherm K15 Rainscreen Board fixed to a 12mm Euroform Versapanel cement particle board
  • Two layers of 12.5mm British Gypsum Gyproc plasterboard fixed to 150mm SFS
Test Report BS 8414-2: 2005 test report - 303930 Download here
Classification Report BR 135: 2013 - 297211 Download here
BS8414_K15_A2CASSETTE

Tested Build-up:

  • 30mm Argeton Tampa terracotta tile fixed with Argeton Tampa clips to an Argeton aluminium vertical support railing system
  • Argeton helping hand bracket
  • AIM VRB Plus horizontal intumescent expanding cavity barrier
  • 140mm Kingspan Kooltherm K15 Rainscreen Board fixed to a 12mm Euroform Versapanel cement particle board
  • Two layers of 12.5mm British Gypsum Gyproc plasterboard fixed to 150mm SFS
Test report BS 8414-2: 2005 - P100184-1000 Download here
Classification report BR 135: 2013 - P100184-1001 Download here
 
BS8414_K15_A2CASSETTE

Tested Build-up:

  • Booth Muirie BML 400 rivet fixed 4mm Mitsubishi ALPOLIC/fr ACM panel (category 2 core material), with 4mm joints, to an aluminium vertical support railing system
  • Siderise RH25G 90/30 horizontal open state cavity barrier with intumescent strip
  • Siderise RSV 90/30 vertical cavity barrier
  • Aluminium helping hand bracket
  • 100mm Kingspan Kooltherm K15 Rainscreen Board fixed to 100mm blockwork substrate
Test report BS 8414-1: 2015+A1 2017 - P107017-1000 Download here
Classification report BR 135: 2013 - P107017-1001 Download here 
BS8414_K15_A2CASSETTE

Tested Build-up:

  • Booth Muirie BML 100-HP (Hook Plate System) 3mm powder coated aluminium cassette panel
  • Booth Muirie BML 100-HP (Hook Plate System) vertical aluminium Y rail
  • Siderise RH25 S-90/30 intumescent horizontal cavity barrier
  • Siderise RV25 S-90/30 vertical cavity barrier
  • Siderise open state cassette insert
  • 100mm Kingspan Kooltherm K15 Rainscreen Board fixed to 100mm blockwork substrate
Test report BS 8414-1: 2015+A1 2017 - DLR1448 Download here
Classification report BR 135: 2013 - SR0810 Download here
BS8414_K15_A2CASSETTE

Tested Build-up:

  • 4mm Mitsubishi ALPOLIC/fr ACM cassette panel
  • Booth Muirie BML 100-HP (Hook Plate System) vertical aluminium Y rail
  • Siderise RH25G 90/30 intumescent horizontal cavity barrier 
  • Siderise RSV 90/30 vertical cavity barrier 
  • Siderise open state cassette insert
  • 100mm Kingspan Kooltherm K15 Rainscreen Board fixed to 100mm blockwork substrate
Test report BS 8414-1: 2015+A1 2017 - DLR1453 Download here
Classification report BR 135: 2013 - SR0811 Download here
K15 with A2 ACM 20mm joints

Tested Build-up:

  • 4mm thick Alpolic A2 ACM panels (Booth Murie BML 400 rivet fixed) with 20mm joints
  • Siderise Lamatherm RH25G-90/30 stone wool horizontal cavity barriers with intumescent strip
  • Siderise Lamatherm RV-90/30 stone wool vertical cavity barriers
  • Galvanised steel ‘U’-shaped channels
  • 100mm Kingspan Kooltherm K15 Rainscreen board fixed to 12mm thick Versapanel cement particle board
  • Two layers of 12.5mm plasterboard fixed to Kingframe SFS comprising galvanised, cold formed steel ‘C’ & ‘U’-sections with 100 x 50mm studs
                                                                               
Test report BS 8414-2: 2015 + A1:2017 - P109938-1000 Dowload here
Classification report BR 135: 2013 - P109938-1001 Download here 
BS8414_K15_A2CASSETTE

Tested Build-up:

  • Booth Muirie BML 400 rivet fixed 4mm Mitsubishi ALPOLIC/fr ACM panel (category 2 core material) with 10mm joints, to an aluminium vertical support railing system
  • Siderise RH25G 90/30 horizontal open state cavity barrier with intumescent strip 
  • Siderise RSV 90/30 vertical cavity barrier
  • Aluminium helping hand bracket
  • 100mm Kingspan Kooltherm K15 Rainscreen Board fixed to 100mm blockwork substrate
Test report BS 8414-1: 2015+A1 2017 - P109939-1000 Download here
Classification report BR 135: 2013 - P109939-1001 Download here
BS8414 K15 BRICK

Tested Build-up:

  • Wienerberger Waresley Red Stock bricks
  • Siderise Lamatherm RH25G-90/30 stone wool horizontal cavity barriers with intumescent strip
  • Siderise Lamatherm EW-CB30 stone wool vertical cavity barriers
  • 50mm cavity
  • 100mm Kingspan Kooltherm K15 Rainscreen board* fixed to Kingspan nilvent breather membrane and 12mm thick Versapanel cement particle board
  • Two layers of 12.5mm plasterboard fixed to Kingframe SFS comprising galvanised, cold formed steel ‘C’ -sections with 100 x 50mm vertical studs
*A small area had Kingspan Kooltherm K15 Rainscreen board in an 80mm thickness.

Test report BS 8414-2: 2015 + A1:2017 - P112065-1000 Download here
Classification report BR 135: 2013 - P112065-1001 Download here
BS8414 K15 4mm A2 ACM

Tested Build-up:

  • 4mm thick Alpolic A2 ACM panels (Booth Murie BML 400 rivet fixed) with 10mm joints fixed to aluminium ‘T’ and ‘L’ rail
  • Siderise RH25G 90/30 horizontal open state cavity barrier with intumescent strip
  • Siderise RSV 90/30 vertical cavity barrier
  • Aluminium helping hand bracket
  • Horizontal 60mm Aluminium top hat (insulated with the 60mm Kingspan Kooltherm K15 Rainscreen Board)
  • 160mm Kingspan Kooltherm K15 Rainscreen Board in two layers at 100mm and 60mm fixed to a 12mm Euroform Versapanel cement particle board with a nilvent breathable membrane on the face of the cement board
  • Two layers of 12.5mm plasterboard fixed to Kingframe SFS

Test report BS 8414-2: 2015 + A1:2017 - DLR1558 Rev.0 Download here
Classification report BR 135: 2013 - SR0966 Rev.0 Download here
BS8414_K15_A2CASSETTE

Tested Build-up:

  • Booth Muirie BML 400 rivet fixed 4mm Mitsubishi ALPOLIC/A2 ACM panel with 20mm joints, to an aluminium vertical support railing system
  • Siderise RH25G 90/30 horizontal open state cavity barrier with intumescent strip
  • Siderise RSV 90/30 vertical cavity barrier
  • Aluminium helping hand bracket
  • 100mm Kingspan Kooltherm K15 Rainscreen Board fixed to 100mm blockwork substrate
Test report BS 8414-1: 2015+A1 2017 - P109971-1000 Download here
Classification report BR 135: 2013 - P109971-1001 Download here

(Reports prepared for Mitsubishi Chemical Corporation, 1-1 Manurouchi 1-chrome, Chiyoda-ku, Tokyo 100-8251, Japan.)
BS8414_K15_A2CASSETTE

Tested Build-up:

  • 4mm Mitsubishi ALPOLIC/A2 ACM cassette panel
  • Booth Muirie BML 100-HP (Hook Plate System) vertical aluminium Y rail
  • Siderise RH25 90/30 intumescent horizontal cavity barrier
  • Siderise RV25 90/30 vertical cavity barrier
  • Siderise open state cassette insert
  • 100mm Kingspan Kooltherm K15 Rainscreen Board fixed to 100mm blockwork substrate
Test report BS 8414-1: 2015+A1 2017 - P109973-1000 Download here
Classification report BR 135: 2013 - P109973-1001 Dowbload here 

(Reports prepared for Mitsubishi Chemical Corporation, 1-1 Manurouchi 1-chrome, Chiyoda-ku, Tokyo 100-8251, Japan.)
K15 ACM - Block 1mm 3

Tested Build-up:

  • CAREA® Acantha grooved panel cladding fixed to a horizontal support railing system on helping hand brackets
  • 140mm Kingspan Kooltherm® K15 Rainscreen Board fixed to a 12mm cement based calcium sheathing board
  • Two layers of 12.5mm plasterboard mechanically fixed to 150mm SFS
Test report BS 8414-2: 2005 - 302995 Download report
Classification report BR 135: 2013 - P100769-1000 Download report 

(Reports prepared for CAREA® Façade, ZA Bel Air, 49520, Combrée, France. (UK Office: CAREA® Ltd, 85 Fleet Street, 7th Floor, London EC4Y 1AE)) 
BS8414_K15 Brick slip cladding with STOFIX finish (render2)_TWELVE

Tested Build-up:

  • Stofix ventilated brick cladding system on horizontal rails secured to a Stofix vertical railing system using Stofix right angle brackets
  • Two layers of 60mm Kingspan Kooltherm® K15 Rainscreen Board fixed to 12 mm cement particle sheathing board
  • Two layers of 12.5mm plasterboard fixed to 100 mm SFS
Test report BS 8414-2: 2005 - 303931
Classification report BR 135: 2013 - P100576-1000

(Reports prepared for Stofix Oy, Lentokatu 2, 90460 Oulu, Finland. (UK Office: Stofix UK Ltd, St. James House, 13 Kensington Square, London W8 5HD))
K15 GEBRIK insulated brick cladding (render3) THIRTEEN v2

Tested Build-up:

  • 60mm Gebrik cladding panels comprising 43mm rigid polyurethane foam behind 17mm brick
    slips fixed to the inner sheathing board
  • 120mm Kingspan Kooltherm® K15 Rainscreen Board fixed to a 12mm sheathing board
  • Two layers of 12.5mm plasterboard fixed to 150mm Kingspan Kingframe® SFS filled with rock mineral fibre.
Test report BS 8414-2: 2005 - P100838-1000 Download here
Classification report BR 135: 2013 - P100838-1001 Download here

(Reports prepared for Aquarian Cladding Systems, Eversea Business Centre, 13 Gardens Road, Clevedon, North Somerset BS21 7QQ and Isosystems, Malmedyer Weg 62, B–4770, AMEL–Schoppen, Belgium)
K5 BS 8414

Tested Build-up:

  • Masonry Substrate
  • 5mm M.R. Bedding Adhesive
  • 60mm Kingspan Kooltherm K5 External Wall Board with mechanical fixings
  • 3 mm M.R. Scrim Adhesive with Alumasc Reinforcement bedded into it
  • 8 – 10 mm M.R. S4 Base Coat
  • Alumasc Silicon Primer
  • 1.5 mm Silkolitt Silicon Render
Test Report BS 8414-1: 2015 + A1: 2017 - P112107-1000
Classification Report BR 135: 2013 - P112107-1001 297211

(Reports prepared for Alumasc Exterior Building Products Ltd, White House Works, Bold Road,
Sutton, St Helens, Merseyside, WA9 4JG.)

Insulated Panel Systems

Kingspan_QC_AWP_MR_Slim_Recess_Render_Image 2_UK_EN

QuadCore® Architectural Wall Panels

Tested specification
 
  • Substrate: Lightweight steel frame
  • Insulation: 70mm Kingspan AWP QuadCore® insulation core
  • Fire breaks / Cavity barriers: No cavity barriers used

Classification Report BR 135: 2013 Annex B - P107923-1001 - Download here

Structural Insulated Panels

Kingspan TEK Cladding Panel

Tested Build-up:

  • Double layer plasterboard
  • Firestops
  • 142 mm Kingspan TEK Cladding Panel
  • 9 mm thick magnesium oxide board
  • Kingspan nilvent
  • Envirograf CV30/4 fire barrier
  • 3 mm aluminium cassette panel
 
Test Report: BS 8414-2: 2015 + A1: 2017 - DLR1552 Rev.0
Classification Report : BR 135: 2013 - SR0965 Rev.0
 

Systems which have not met the requirements of BR 135

This section contains reports of BS 8414 tests with systems that have failed to meet the requirements of BR 135. Please refer to the list above, as some of the combinations of materials tested below have met the requirements of BR 135 in specific system configurations.
 
  • 100mm Kingspan Kooltherm K15 Rainscreen Board on SFS with Alpolic A2 ACM with panels 1150mm in height and 998m in width.
  • 100mm Kingspan Kooltherm K15 Rainscreen Board with Dri-Design Aluminum Cassette.
  • Vitracore G2 ACM with 180mm Rockwool Duo Slab Insulation
    • BS 8414-1:2015 + A1 :2017 test report: DLR1516 Rev.0
    • Classification Report as per BR135:2013 Annex A Tested as per BS 8414-1: 2015 + A1:2017: SR0894 Rev.0 
  • 100mm Kingspan Kooltherm K15 Rainscreen Board with Dri-Design Aluminum Cassette.
  • 100mm PIR Karrier Panel with Thermatile tile rainscreen
    • BS 8414-2: 2005 test report270772
  • 160mm Kingspan Kooltherm K15 Rainscreen Board with Alpolic A2 ACM Cassette Panel.

Contact our technical experts