Management Standards
Standard |
Management System |
ISO 9001:2015 |
Quality Management |
ISO 14001:2015 |
Environmental Management |
ISO 45001:2018 |
Health and Safety Management |
ISO 50001:2011 |
Energy Management |
Kingspan Therma TR27 are also manufactured to the highest standards in accordance with the requirements of:
Requirement |
Rigid polyisocyanurate (PIR) and polyurethane(PUR) products for building end–use applications |
BS 4841-3 |
Specification for laminated boards (roofboards) with auto–adhesively or separately bonded facings for use as roof board thermal insulation under built–up bituminous roofing membranes |
BS 4841-4 |
Specification for laminated boards (roofboards) with auto–adhesively or separately bonded facings for use as roofboard thermal insulation under single−ply roofing membranes |
Spanning On Metal Decks
Trough Opening (mm) |
Minimum Insulant Thickness (mm) |
≤75 |
25 |
76 - 100 |
30 |
101 - 125 |
35 |
126 - 150 |
40 |
151 - 175 |
45 |
176 - 200 |
50 |
201 - 225 |
55 |
226 - 250 |
60 |
Product Testing
Characteristic |
Standard |
Result |
Compressive Strength |
AS 2498.3 |
Typically exceeds 150 kPa at 10% compression |
Water Vapour Resistance |
AS 2498.5 |
> 7 MN·s/g·m |
Fire Performance
Kingspan Therma TR27, when subjected to the British and Australian Standard fire test specified in the table below, will achieve the result shown, when waterproofed with a single–ply waterproofing membrane.
Test |
Result |
BS 476-3: 2004
(External fire exposure roof test) |
Dependent on single-ply membrane adopted |
AS 1530.3
(Ignitability, Flame Spread, Heat Release, Smoke Release) |
Spread of Flame Index: 0
Smoke Development Index: 1 |
AS 2122.1
(Flame Propagation AS 1366) |
Complies |
Kingspan Therma TR27, when subjected to the British Standard fire test, specified in the table below, will achieve the result shown when waterproofed with 3 layer built–up felt and a loading coat of 10 mm chippings. For specifications without the chippings please consult the manufacturer of the mineral surfaced cap sheet for their fire classification details.
Test |
Result |
BS 476-3: 2004
(External fure exposure roof test) |
FAA Rating |
Further details on the fire performance of Kingspan Insulation products may be obtained from the
Kingspan Insulation Technical Service.
Environmental Data Table
Recyclability |
Non-contaminated insulation site waste is recyclable, but there are currently no facilities in Australia to process returned material |
Re-usability |
Re-usable if removed with care (long term of service expected) |
Water Use |
No water used in Kingspan Insulation's manufacturing process |
Blowing Agent Global Warming Potential (GWP) |
Manufactured with a blowing agent that has low GWP |
Blowing Agent Ozone Depletion Potential (ODP) |
Manufactured with a CFC/HCFC-free blowing agent that has zero ODP |
Packaging |
Contains 0% recycled product
Polythene wrap and EPS skids 100% recyclable |