Download
KarrierPanel H Quad Core Intermediate Support Render KarrierPanel H Quad Core Intermediate Support Render
Previous
Next

Details

KarrierPanel is a cost-effective universal barrier wall alternative solution to traditional multi-component wall systems. KarrierPanel utilizes Kingspan’s fully engineered KarrierRail to securely and safely transmit loads from a wide range of façade options to the structural supports behind the insulated panel.

Our KarrierPanel series:

  • Allows for faster building close-in and dry-in for reduced building costs
  • Eliminates thermal-bridging energy losses associated with standard stud/cavity insulation construction
  • Reduces delays in construction experienced with scheduling multiple trades
  • Brick Ties can also be integrated to combine the look of masonry with the benefits of an insulated metal panel
  • GREENGUARD Gold Certified
  • Certified material transparency and disclosure (QuadCore only)
  • Red List Free classification (QuadCore only)

Now available with QuadCore Technology

It's all in the gray cells - learn about the QuadCore difference here.

​KarrierPanels can now be equipped with QuadCore™ Technology, Kingspan’s next generation
self-blended hybrid insulation core.

Our top-of-the-line QuadCore insulation is now an option on all KarrierPanels, in addition to the standard PIR core option.
QuadCore_Cell_Icons_small_NA

Product Information

Product Specification
R-Value
QuadCore Testing
PIR Testing
Warranty
Colours
Profile Exterior: Shadowline or flat
Interior: Shadowline
Embossing Exterior: Stucco or non-embossed
Interior: Stucco or non-embossed
Gauge Exterior: 26, 24, 22 ga
Interior: 26, 24, 22 ga
Width 24”, 30”, 36”, 40”, 42”
Thickness 2”, 2.5”, 3”, 4”, 5”, 6”
Length 8' - 53'
Reveal option ⅜" to accommodate rail
Orientation Vertical or horizontal
Post fabrication N/A
R-value ≈ 7.2 per inch per ASTM C518 @ 75˚F
≈ 8.25 per inch per ASTM C518 @ 35°F
Insulation Core R-value
QuadCore Technology ≈ 8 per inch per ASTM C518 @ 75˚F
PIR ≈ 7.2 per inch per ASTM C518 @ 75˚F
≈ 8.25 per inch per ASTM C518 @ 35°F
Test Procedure Results
Fire ASTM E84 Flame Spread: 25 or Less / Smoke Developed: 450 or Less
CAN/ULC-S102 Flame Spread: 20 / Smoke Developed: 350 for panel with facings
CAN/ULC S127 Flame Spread: <500 for foam core
NFPA 259 Tested for potential heat of building materials
NFPA 268 Passed: Standard test method for determining ignitability of exterior wall assemblies using a radiant heat energy source
NFPA 285 Passed: Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
Structural ASTM E72 Vacuum chamber tested. Panel load / span and deflection tables are available
Thermal Transmission ASTM C518
Thermal Performance at 75°  
Thickness U-Factor R-Value
2 0.06 16.0
2.5 0.05 20.0
3 0.04 24.0
4 0.03 32.0
5 0.03 40.0
6 0.02 48.0
Air Infiltration ASTM E283 0.003 CFM/ft2 of Panel Area at 6.24 psf
Water ASTM E331 No uncontrolled water penetration at 20 psf differential pressure
AAMA 501.1 Dynamic water pressure testing – no sign of water leakage at 15 psf
Bond Strength ASTM D1623 Panels tested for tensile bond strength of metal to foam
Sample placed in an autoclave device and pressurized to 2 PSI at 212°F for 2½ hours
Skin Delamination   No skin delamination with direct pull off pressure up to 1188 psf
The following testing applies to the barrier wall panel only.
 
Test Procedure Results
Fire ASTM E84 Flame Spread: 25 or Less / Smoke Developed: 450 or Less
CAN/ULC-S102 Flame Spread: 20 / Smoke Developed: 350 for panel with facings
CAN/ULC-S127 Flame Spread: <500 for foam core
NFPA 259 Tested for potential heat of building materials
NFPA 268 Passed: Standard test method for determining ignitability of exterior wall assemblies using a radiant heat energy source
NFPA 285 Passed: Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
Structural ASTM E72 Vacuum chamber tested. Panel load / span and deflection tables are available
Thermal Transmission ASTM C518
Thermal Performance at 75°   Thermal Performance at 35°
Thickness U-Factor R-Value Thickness U-Factor R-Value
2 0.07 14.4 2 0.06 16
2.5 0.06 18.0 2.5 0.05 20
3 0.05 21.6 3 0.04 24
4 0.03 28.8 4 0.03 32
5 0.03 36.0 5 0.03 40
6 0.02 43.2 6 0.02 48
Air Infiltration ASTM E283 0.003 CFM/ft² of Panel Area at 6.24 psf
Water ASTM E331 No uncontrolled water penetration at 20 psf differential pressure
AAMA 501.1 Dynamic water pressure testing – no sign of water leakage at 15 psf
Fatigue Tests Cyclic test to positive and negative wind loading to ± L/180 deflection The panels exceeded 2 million alternate cycles without failure or damage
Bond Strength ASTM D1623 Panels tested for tensile bond strength of metal to foam
Sample placed in an autoclave device and pressurized to 2 PSI at 212 °F for 2½ hrs
No skin delamination with direct pull off pressure up to 1188 psf


At Kingspan, we understand the unique challenges that design and construction professionals face every day.  To do our part in meeting these demands, Kingspan products are offered with our team’s guidance and technical expertise, followed up after construction is completed with our product warranties:
 

  • 2 year standard material workmanship warranty
  • Up to 20 years standard finish warranty
 
Contact our sales or customer service departments for information regarding our optional warranty programs.

Insulated_panel_systems_colors
KarrierPanel_Profile Render_KP_NA

Featured Projects

Downloads

KarrierPanel Brochure

Insulated Panel Systems Product Selector

Colour Chart

Be Inspired Global Case Study Book

KarrierPanel Data Sheet

KarrierPanel Horizontal CAD Details (DWG)

KarrierPanel Horizontal CAD Details (PDF)

KarrierPanel Vertical CAD Details (DWG)

KarrierPanel Vertical CAD Details (PDF)

KarrierPanel Horizontal Flat Rail CAD Details (DWG)

KarrierPanel Horizontal Flat Rail CAD Details (PDF)

KarrierPanel Vertical Flat Rail CAD Details (DWG)

KarrierPanel Vertical Flat Rail CAD Details (PDF)

KarrierPanel Brick CAD Details (DWG)

KarrierPanel Brick CAD Details (PDF)

KarrierPanel Installation Guide

Environmental Product Declaration - PIR

Environmental Product Declaration - QuadCore

For the complete building envelope solution, consider these complementary products.

Support & Training

Can we help or provide a sample?

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click "Accept and close" to accept the use of cookies on our website. If you do not click "Accept and close" but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.

The Cookie Policy & Control and Website Privacy Notice were updated on 13 August 2018.