Kerry_Foods_Jackson_WI_with QuadCore_overlay_KSSL_KSSLI_US

KS Shadowline Wall Panel

QuadCore_Cell_Icons_small_NA

Now available with QuadCore Technology

It's all in the gray cells - learn about the QuadCore difference here.
Download
KS Shadowline QuadCore CS Intermediate Support KS Shadowline QuadCore CS Intermediate Support
Previous
Next

KS Shadowline Wall Panel

Available in 24”, 30”, 36” and 42” module widths, KS Shadowline is designed to offer the highest R-value for controlled environment/cold storage needs. Meeting USDA guidelines, Imperial White Siliconized Modified Polyester is the standard finish for KS Shadowline making it ideal for food processing projects.

  • Designed to meet today’s high performance standards in a wide variety of environments
  •  Available in 26, 24 and 22 gauge to meet most design and span requirements
  • KS Shadowline’s tongue and groove interlocking rainscreen joint provides supreme foam-to-foam contact and thermal protection
  • Conveniently produced in multiple Kingspan manufacturing locations
  • Suitable for both interior and exterior application
  • GREENGUARD Gold Certified
  • Certified material transparency and disclosure (QuadCore only)
  • Red List Free classification (QuadCore only)
KS_Shadowline_Cold_Storage_Profile_Render_KSSL_NA

Product Information

Product Specification
R-Value
QuadCore Testing
PIR Testing
Warranty
Colors
Profile Exterior: Shadowline
Interior: Shadowline
Embossing Exterior: Stucco or non-embossed
Interior: Stucco or non-embossed
Gauge Exterior: 26, 24, 22 ga
Interior: 26, 24, 22 ga
Width 24”, 30”, 36”, 42”
Thickness 2”, 2.5”, 3”, 4”, 5”, 6”
Length 8’ - 53’
Reveal option Vertical: ⅛”
Horizontal: ⅛” or ⅜"
Orientation Vertical or horizontal
Post fabrication Trimless ends, folded corners 
Insulation Core R-value
QuadCore Technology ≈ 8 per inch per ASTM C518 @ 75˚F
PIR ≈ 7.2 per inch per ASTM C518 @ 75˚F
≈ 8.25 per inch per ASTM C518 @ 35°F
Test Procedure Results
Fire FM-4880 Passed: Class 1 Fire Rating of Insulated Wall or Wall and Roof / Ceiling Panels, Interior Finish Materials or Coatings, and Exterior Wall Systems
FM-4882 Passed: Class 1 Interior Wall and Ceiling Materials or Systems for Smoke Sensitive Occupancies
ASTM E84 Flame Spread: 25 or Less / Smoke Developed: 50 or Less
CAN/ULC-S101 Fire Endurance Tests: 10 min
CAN/ULC-S102 Flame Spread: 20, Smoke Developed: 45 for panel with facings
CAN/ULC S138 Passed: Fire growth of foamed plastic insulated building panels in a full scale room configuration
CAN/ULC-S134 Passed: Standard method of test for fire of exterior wall assemblies
NFPA 259 Tested for potential heat of building materials
NFPA 285 Passed: Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
Structural FM-4881 Passed: Class +110/-154 Zone H Class +100/-140 Zone HM – LM
ASTM E72 Vacuum chamber tested. Panel load / span and deflection tables are available
Thermal Transmission ASTM C518
Thermal Performance at 75°  
Thickness K-Factor R-Value
2 0.063 16.0
2.5 0.050 20.0
3 0.042 24.0
4 0.031 32.0
5 0.025 40.0
6 0.021 48.0
Air Infiltration ASTM E283 0.003 CFM/ft2 of Panel Area at 6.24 psf
Water ASTM E331 No uncontrolled water penetration at 20 psf differential pressure
AAMA 501.1 Dynamic water pressure testing – no sign of water leakage at 15 psf
Bond Strength ASTM D1623 Panels tested for tensile bond strength of metal to foam
Sample placed in an autoclave device and pressurized to 2 PSI at 212°F for 2½ hours
Skin Delamination  
No skin delamination with direct pull off pressure up to 1188 psf
Test Procedure Results
Fire FM-4880 Passed: Class 1 Fire Rating of Insulated Wall or Wall and Roof / Ceiling Panels, Interior Finish Materials or Coatings, and Exterior Wall Systems
ASTM E84 Flame Spread: 25 or Less / Smoke Developed: 450 or Less
CAN/ULC-S101 Fire Endurance Tests: 10 min and 15 min stayed in place
CAN/ULC-S102 Flame Spread: 5 / Smoke developed: 135 for panel with facings
CAN/ULC-S127 Flame Spread: <500 for foam core
CAN/ULC S138 Passed: Fire growth of foamed plastic insulated building panels in a full scale room configuration
CAN/ULC-S134 Passed: Standard method of test for fire of exterior wall assemblies
NFPA 259 Tested for potential heat of building materials
NFPA 268 Passed: Standard test method for determining ignitability of exterior wall assemblies
using a radiant heat energy source
NFPA 285 Passed: Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components
Structural FM-4881 Passed: Class +110/-154 Zone H Class +100/-140 Zone HM – LM
ASTM E72 Vacuum chamber tested. Panel load / span and deflection tables are available
Thermal Transmission ASTM C518
Thermal Performance at 75°   Thermal Performance at 35°
Thickness U-Factor R-Value Thickness U-Factor R-Value
2 0.07 14.4 2 0.06 16
2.5 0.06 18.0 2.5 0.05 20
3 0.05 21.6 3 0.04 24
4 0.03 28.8 4 0.03 32
5 0.03 36.0 5 0.03 40
6 0.02 43.2 6 0.02 48
Air Infiltration ASTM E283 0.003 CFM/ft² of Panel Area at 6.24 psf
Water ASTM E331 No uncontrolled water penetration at 20 psf differential pressure
AAMA 501.1 Dynamic water pressure testing – no sign of water leakage at 15 psf
Fatigue Cyclic test to positive and negative wind loading to ± L/180 deflection The panels exceeded 2 million alternate cycles without failure or damage wind loading to ± L/180 deflection wind loading to ± L/180 deflection
Bond Strength ASTM D1623 Panels tested for tensile bond strength of metal to foam
Skin Delamination   Sample placed in an autoclave device and pressurized to 2 PSI at 212 °F for 2½ hrs
No skin delamination with direct pull off pressure up to 1188 psf


Standard Material Workmanship & Standard Finish Warranties

At Kingspan, we understand the unique challenges that design and construction professionals face every day.  To do our part in meeting these demands, Kingspan products are offered with our team’s guidance and technical expertise, followed up after construction is completed with our product warranties:
 
  • 2 year standard material workmanship warranty
  • Up to 20 years standard finish warranty
 

QuadCore 30-Year Thermal Warranty

Only available with KS Micro-Rib and KS Shadowline

​The industry’s longest thermal performance warranty. The inimitable science behind QuadCore™ Technology and comprehensive independent third-party testing has delivered the industry an unparalleled 30-year thermal performance warranty.

Contact our sales or customer service departments for information regarding our optional warranty programs.

QuadCore_Kingspan_Warranty_Badge_NA

Download our QuadCore Warranty Document

Controlled_environments_colors_NA

Downloads

Controlled Environments Product Selector

QuadCore Brochure

Colour Chart

HERCULES Door Brochure

Be Inspired Global Case Study Book

KS Shadowline Data Sheet

KS Series Weight Table

KS Shadowline Load Span Table

KS Series MasterFormat CSI Specification (DOC)

KS Series MasterFormat CSI Specification (PDF)

KS Series Vertical Cold Storage CAD Details (DWG)

KS Series Vertical Cold Storage CAD Details (PDF)

Featured Projects

For the complete controlled environments building envelope solution, consider these complementary products.

Support & Training

Can we help or provide a sample?

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click "Accept and close" to accept the use of cookies on our website. If you do not click "Accept and close" but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.

The Cookie Policy & Control and Website Privacy Notice were updated on 13 August 2018.