Test |
Procedure |
Results |
Fire |
FM 4880 |
Passed: Class 1 Fire Rating of Building Panels or Interior Finish Materials* |
ASTM E84 |
Flame spread: 25 or Less, Smoke developed: 450 or Less |
ULC-S102 |
Flame Spread: 20 / Smoke Developed: 165 for panel insulation core |
ULC-S126 |
Passed: Standard Method of Test For Fire Spread Under Roof-Deck Assemblies |
ULC-S138 |
Passed: Standard Method of Test For Fire Growth Of Insulated Building Panels In A Full-Scale Room Configuration |
Wind Uplift |
FM 4471 |
Class 1-60 - RoofNav Assembly #317601-0-0*
Class 1-90 - RoofNav Assembly #278783-0-0*
Class 1-105 - RoofNav Assembly #317604-0-0*
Class 1-135 - RoofNav Assembly #317605-0-0* |
UL 580 Class 90 uplift rating |
5’0” spans with minimum 16 gauge purlins |
Strength |
ASTM E72 Chamber Method |
Panel load / span and deflection tables are available |
Thermal Transmission |
ASTM C518 |
Thermal Performance at 75° mean temperature |
|
Thermal Performance at 40° mean temperature |
Thickness |
U-Factor |
R-Value |
Thickness |
U-Factor |
R-Value |
3.25 |
0.043 |
23 |
3.25 |
0.040 |
25 |
4 |
0.034 |
29 |
4 |
0.032 |
31 |
5 |
0.028 |
36 |
5 |
0.026 |
39 |
6 |
0.023 |
43 |
6 |
0.022 |
46 |
|
Air Infiltration |
ASTM E1680 |
0.01 CFM/ft2 of Panel Area @ 12 psf |
Water Penetration |
ASTM E331 and ASTM E1646 |
No Water Penetration at 20.0 psf |
*Thickness: 3.25”-6”, Width: 40”, Min. gauge: Exterior 26 ga, Interior 26 ga.
For FM compliance, systems must be installed in accordance with FM installation specifications as detailed on RoofNav.com.
Please contact technical.NA@kingspanpanels.com for detailed information or refer to RoofNav.com.