Safepro2

Télécharger
Kingspan_Safepro2_Roof_productrender_03201701_SS_UK (2)
Previous
Next

Aperçu du produit

Ce système est composé d’un câble en acier de haute résistance tendu par des potelets en acier absorbant l’énergie et limitant ainsi la chute jusqu’à 6kN. 
 
1. Respecte pleinement la norme BS EN 795: C.
2. Remplit les critères du test ACR[M]002: 2009 sur les potelets de toit.
3. Intègre une technologie de minimisation de la force de la chute.
4. Résistant à la corrosion.
5. Fixation sans perçage dans l’âme isolante.  
6. Pas besoin d’accès à la face intérieure du toit.   
7. Conçu pour un usage sur les panneaux de toiture et photovoltaïques Kingspan.
8. Peut être installé avant ou après la construction.
9. Garanti jusqu’à 25 ans.

Information technique

Documents
Conformité aux panneaux de toiture isolés Kingspan
Design & spécification – niveaux de protection personnelle
Garantie
  Trapezoidal Lo-Pitch Curved Roof Slate & Tile Support Roof Tile Topdek Sinusoidal KingZip IP 
Safepro2
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  
PPE Level Summary Description Application Example
1 Restraint without requirement for PPE adjustment.  Workers are restrained from reaching all fall hazards by attaching themselves to the fall protection system with PPE that requires no manual adjustment. 

The system, as installed, should be proven capable of arresting falls. 
System is fixed 2.5m back from the edge of a low pitch roof. 

Worker is using a 2m long lanyard. 

Within 5m of the roof edge, the worker is restrained from reaching the edge without the need to adjust PPE. 

For roof locations over 5m from the edge, there is negligible risk of a fall. There is no need for PPE attachment. 
 
2 Restraint with requirement for PPE adjustment.  Workers are restrained from reaching all fall hazards by attaching themselves to the fall protection system with PPE that requires correct manual adjustment. 

The system, as installed, should be proven capable of arresting falls. 
System is fixed centrally on a roof. 

Worker uses a rope with a grab. 

For protection when accessing different areas of the roof, workers should manually adjust the length of their connection to the system. 

Incorrect adjustment may result in a fall. 
 
3 Fall arrest.  Workers are not restrained from reaching fall hazards, but any fall occurance will be arrested in a controlled manner. 

Fall clearance must be taken into consideration, and a rescue plan must be implemented before work begins. 
 
A narrow roof area where it is not possible to prevent workers from reaching the edge, even when they are connected to a fall protection system. 

In a single unique package, we cover the performance of your insulated panels and ancillary products in the following areas:

  • Coating performance - up to 40 years

  • Fire performance - up to 25 years

  • Thermal performance - up to 25 years

  • Structural performance - up to 25 years

  • Acoustic performance - up to 25 years

Kingspan_Safepro2_on_TD_SP_UK

Accessoires du systèmes et services

Nous fabriquons et entretenons le système de toit complet, y compris des éléments de construction pour tous les accessoires (voir les détails CAO ci-après). Contactez-nous pour des services complémentaires comprenant : Spécifications particulières de projet NBS, conseils de sécurité incendie et performance acoustique, éléments de construction sur mesure, valeur U/risque de condensation, panneau avec portée, fixation et calculs du drainage du toit, concepts d’éclairage optimisés.

Kingspan_Topdek_Flat_Roof_SystemRender_TD_032017_UK

Contact