AIR-CELL Insuliner Wedge

Reflective Insulation For Use as Wall/Ceiling Lining

Kingspan AIR-CELL Insuliner is the latest in thermo reflective insulation technology with the most advanced fire performance characteristics, achieving a Group 2 classification to NCC fire ratings for wall and ceiling linings. Kingspan AIR-CELL Insuliner comprises a cross-linked, closed-cell insulation core sandwiched by highly reflective foil facings.

  • Australian made
  • Group 2 NCC fire classification
  • Designed for warehouses and commercial or industrial sheds where the insulation acts as the wall or ceiling lining
  • 3-in-1 insulation, vapour barrier and radiant barrier

Product Information

Product Data Table
R-values
Specification Guide
Installation Instructions
CAD Drawings
Testing and Data Table
Product Data 
Product Thickness 5.5 mm
Roll Diameter 400mm
Roll Weight 9 kg
Roll Size 1350 mm x 22.25 m (30 m2)
Reflectance  Anti-glare: 95%
Reflective: 97%
Emittance Anti-glare: E0.05
Reflective: E0.03
Max. Span Distance 1200 mm under sheet roof without support mesh

Technical Service

If your construction is different from those specified, and/or to gain a comprehensive R-value calculation and technical information of your project, please consult the Kingspan Insulation Technical Service Department for assistance. Call 1300 247 235 and press "2" to speak with Technical services, email technical@kingspaninsulation.com.au, or use the online contact form.


Assumption and Key

The R-values shown are Total R-values for the building element as required by the Energy Provisions of the Building Code of Australia. Kingspan AIR-CELL products are manufactured, tested and packaged in conformance with AS/NZS 4859.1.

The contribution of the product Total R-values depends on installation and environmental conditions. The R-value will be reduced in the event of the accumulation of dust on the upward facing surfaces and in those cavities that are ventilated.

Commercial Metal Deck Roof

View System R-value

Commercial Metal Deck Roof Retrofit

View System R-value

Warehouse Wall

View System R-value

Warehouse Wall Retrofit

View System R-value

General Requirements

  1. Fit Kingspan AIR-CELL neatly around doors, windows, and any penetrations, and tape if necessary to prevent air leakage.
  2. When taping a plastic squeegee or blade must be used to apply appropriate pressure to the tape. Surfaces must be dry and free from dust, oil or grease prior to taping (please refer to brochure ‘Kingspan Insulation Tape’ for further information).
  3. Leave minimum 50 mm clearance around heat producing flues or light fittings (refer to light fitting manufacturer).
     
The instructions in this document are guidelines only and should be interpreted with consideration for the specific building design. The installation of Kingspan AIR-CELL should be in conformance with the applicable clauses from AS 3999 and AS/NZS 4200.2 unless otherwise specified.
 
Kingspan AIR-CELL can be damaged by intense heat above 105° C and contact with sparks and flame from blow torches, welders, cutting tools, etc. must be avoided.
 
The installer must make due provision for safety when installing Kingspan AIR-CELL in any application.

Safety Information

View Safety Information

Handling & Storage

View Instructions

Commercial Metal Deck Roof

View Installation Instructions

Commercial Metal Deck Roof Retrofit

View Installation Instructions

Warehouse Wall Retrofit

View Installation Instructions

PDF Format

CAD PDF - Commercial Office Metal Roof

CAD PDF - Warehouse Wall_AIR-CELL

DWG Format

CAD DWG - Commercial Office Metal Roof

CAD DWG - Warehouse Wall_AIR-CELL

Management Standards

Standard Management System
ISO 9001:2008 Quality Management
ISO 14001:2004 Environmental Management


Manufacturing Specifications

Characteristic Test Method / Standard Specification
NCC Group Number AS ISO 9705 Group 2
Flammability Index AS 1530.2 ≤ 5
Material Thermal Resistance ASTM C518 R0.16 m²·K/W
Emittance ASTM E408 Reflective Face E0.03
Anti-Glare Face E0.05
Shrinkage AS/NZS 4201.3 Pass
Dry Delamination AS/NSZ 4201.1 Pass
Wet Delamination AS/NSZ 4201.2 Pass
Water Barrier AS/NSZ 4201.4 High Resistance
Water Absorbency AS/NSZ 4201.6 Unclassified
Corrosion Resistance AS/NZS 4859.1 Appendix I Pass


Environmental Data Table

Aspect  Characteristic
Recyclability Waste not recyclable. Roll width to suit most applications to minimise site waste
Re-usability Re-usable if removed with care (long term of service expected)
Water Use No water used in Kingspan Insulation's manufacturing process
Ozone Depleting Substances None present in the finish product or in Kingspan Insulation's manufacturing process
Packaging Contains approximately 10% recycled product. Packaging is 100% recyclable
Embodied Energy 43 MJ/m² approximately

Latest Case Studies

Do you need help and advice on your project?

Our teams are dedicated to helping you make process as easy as possible and ensure you get the right materials for your needs.

Contact Us

Contact Information

Kingspan Insulation Australia

Kingspan Insulation operates Australia wide. Contact us to find your local State Representative. For any enquiries, call 1300 247 235 or send an email to info@kingspaninsulation.com.au.

Head Office

266 Beringarra Avenue, Malaga

Western Australia

6090

Call: 1300 247 235

Fax: 1300 247 329

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click "Accept and close" to accept the use of cookies on our website. If you do not click "Accept and close" but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.