Insulated Dry-lining Plasterboard for Mechanical Fixing

Kingspan Kooltherm K18 Insulated Plasterboard is a super high performance, fibre-free rigid thermoset phenolic insulation, sandwiched between a front facing of tapered edge gypsum based plasterboard, and a reverse facing of low emissivity foil autohesively bonded to the insulation core during manufacture.

  • Made in Australia
  • 3-in-1 insulation, dry-lining and vapour control
  • Clear cavity is maintained - resists moisture penetration
  • Group 1 NCC fire classification
  • Practical for modular construction 
NCC 2019 compliant brochures and AU made

Total R-value Calculator

Customise your wall, roof and floor systems and produce NCC 2019 Total R-values Reports. Powered by Speckel.

Click here
 

Product Information

Product Data Table
R-values
Specification Guide
Installation Instructions
Downloads
Testing and Data Table
Thermal Conductivity (λ-Value) 0.021 W/m·K at 23oC (Insulant thickness ≥ 45 mm)
0.023 W/m.K at 23oC (Insulant thickness 25 - 44 mm)
0.17 W/m.K at 23oC (Plasterboard Thickness 10 mm) 
Emittance Foil Face E0.14        
Product Dimensions 2400 mm x 1200 mm (2.88 m2)
Other dimension available upon enquiry. Minimum order quantities apply.
Nominal Product
Thickness (inc. Plasterboard)
35, 40, 50, 60, 70, 80, 90 mm
Other thicknesses available upon enquiry. Minimum order quantities apply.
Nominal Plasterboard Thickness 10 mm

Alternative lining boards, such as fibre cement sheets, can also be bonded to the insulation core to create customised finishes and facings in our Kingspan Kooltherm K18+ Insulated Lining Board range. Please contact us for more information.

Technical Service

If your construction is different from those specified, and/or to gain a comprehensive R Value calculation and technical information of your project, please consult the Kingspan Insulation Technical Service Department for assistance. Call 1300 247 235 and press "2" to speak with Technical Services, email technical@kingspaninsulation.com.au, or use the Online Contact Form

Assumption and Key

NCC 2019 prescribes different methods to determine Total R-value Calculations for Volume 1 and Volume 2. The systems noted on this page are Total R-values for the building element as required by the Energy Provisions of the National Construction Code, calculated in accordance with AS/NZS 4859.2 2018 & NZS 4214. Kingspan Kooltherm® products are manufactured, tested and packaged in conformance with AS/NZS 4859.1:2018


Fire Resistance

Examples shown are suitable for NCC Class 1 & 10a housing and Fire-Resisting Construction Type C walls in NCC Class 2 – 9 buildings. For Fire-Resisting Construction Type A & B walls in NCC Class 2 – 9 buildings a Performance Solution is required. Please contact Kingspan Insulation Technical Services on 1300 247 235 or email technical@kingspaninsulation.com.au for further guidance.

Product R-values

View Product R-values

Mechanically Fixed to Timber Rafters (Covered Beams) - Tiled Roof

View System R-value

Mechanically Fixed to Timber Rafters (Covered Beams) - Metal Roof

View System R-value

Mechanically Fixed to Timber Framing

View System R-value

Mechanically Fixed to Internal Side of Steel Frame with Close Jointed Cladding

View System R-value

Mechanically Fixed to Internal Side of Timber Frame with Close Jointed Cladding

View System R-value

Kooltherm K18 Insulated Plasterboard Model Specification

You can also download the comprehensive model specification here.

Handling & Storage

View Instructions

Cutting and Taping

View Instructions

Dry Wall Plasterboard

View Installation Instructions

Mechanical Fixing to Timber Joists or Rafters

View Installation Instructions

Mechanical Fixing to Metal or Timber Frames/Metal Stud and Track/Battens

View Installation Instructions

Mechanical Fixing to Metal Furring Systems

View Installation Instructions

CAD PDF - Residential Tiled Roof Raked Ceiling_Kooltherm

CAD PDF - Residential Tiled Roof Exposed Beam_Kooltherm

CAD PDF - Brick Veneer Wall_Kooltherm K18

CAD PDF - Brick Veneer Wall_AIR-CELL_Kooltherm K18 Combination

CAD PDF - Steel Framed Wall_Kooltherm K18

CAD PDF - Steel Framed Wall_AIR-CELL_Kooltherm K18 Combination

CAD PDF - Timber Framed Wall_Kooltherm K18

CAD DWG - Residential Tiled Roof Raked Ceiling_Kooltherm

CAD DWG - Residential Tiled Roof Exposed Beam_Kooltherm

CAD DWG - Brick Veneer Wall_Kooltherm K18

CAD DWG - Brick Veneer Wall_AIR-CELL_Kooltherm K18 Combination

CAD DWG - Steel Framed Wall_Kooltherm K18

CAD DWG - Steel Framed Wall_AIR-CELL_Kooltherm K18 Combination

CAD DWG - Timber Framed Wall_Kooltherm K18

BIM 2016 - Kooltherm K18 Insulated Plasterboard

BIM 2017 - Kooltherm K18 Insulated Plasterboard

BIM 2018 - Kooltherm K18 Insulated Plasterboard

BIM 2019 - Kooltherm K18 Insulated Plasterboard

Management Standards

Standard Management System
ISO 9001:2015 Quality Management
ISO 14001:2015 Environmental Management
ISO 45001:2018 Health and Safety Management
ISO 50001:2011 Energy Management

Applies only to the Kingspan Kooltherm K10 insulation board used in the manufacture of this composite insulated plasterboard product.


Product Testing

Characteristic Standard Result
Compressive Stress (Insulant) AS 2498.3 Typically exceeds 100 kPa at 10% compression
Water Vapour Resistance BS EN 12086:1997 / I.S. EN 12086:1998 > 35 MN·s/g

For the purpose of calculation of condensation risk, the resistivity of the plasterboard component of the product should be taken as 50MN·s/g·m.


Fire Performance

Test Test Method Result
Ignitability
Spread of Flame Index
Heat Release
Smoke Development
AS 1530.3  Spread of Flame Index: 0
Smoke Development: ≤ 3
NCC Group Number in
accordance with AS 5637.1
AS/NZS 3837
/ Amdt 1
Group 1**
Smoke Obscuration AS/NZS 3837 < 5m2/kg

* Applies only to the Kingspan Kooltherm K10 insulation board used in the manufacture of this composite insulated plasterboard product.
** Applies to compliant plasterboard facing.

Environmental Data Table

Aspect Characteristic
Recyclability Non-contaminated insulation site waste is recyclable, but there are currently no facilities in Australia to process returned material
Re-usability Re-usable if removed with care (long term of service expected)
Water Use No water used in Kingspan Insulation's manufacturing process
Blowing Agent Global Warming Potential (GWP) Manufactured with a blowing agent that has low GWP
Blowing Agent Ozone Depletion Potential (ODP) Manufactured with a CFC/HCFC-free blowing agent that has zero ODP
Packaging Contains 0% recycled product
Polythene wrap and EPS skids 100% recyclable

Latest Case Studies

Do you need help and advice on your project?

Our teams are dedicated to helping you make process as easy as possible and ensure you get the right materials for your needs.

Contact Us

Contact Us

Kingspan Insulation Australia

Kingspan Insulation operates Australia wide. Contact us to find your local State Representative. For any enquiries, call 1300 247 235 or send an email to info@kingspaninsulation.com.au.

Head Office

25 Oherns Road,

Somerton, VIC

3062

Call: 1300 247 235

Fax: 1300 247 329