Download
Air-Cell Insulwhite Wedge
Previous
Next

White-Faced Thermo Reflective Insulation

Kingspan AIR-CELL Insulwhite comprises a cross-linked, closed-cell insulation core sandwiched by a highly reflective foil facing on the upper side and a white facing on the other side. 

Kingspan AIR-CELL Insulwhite is designed for use in attic conversions where a white ceiling-like appearance is desired.

  • Australian made
  • 3-in-1 Insulation, vapour barrier, and radiant barrier
  • Fibre-free
  • Anti-bacterial and anti-fungal
NCC 2019 compliant brochures and AU made

Product Information

Product Data Table
R-values
Specification Guide
Installation Instructions
CAD Drawings
Testing and Data Table
Product Data 
Product Thickness (nom.) 5.5 mm
Product R-value at 23oC R0.15 m2.K/W
Roll Diameter (nom.) 450 mm
Roll Weight (nom.) 7.65 kg
Roll Size  1350 mm x 22.25 m (30 m2)
Reflectance  Reflective face: 97%
Emittance  Reflective face: E0.03
Max Span 2.4m without product support mesh

Technical Service

If your construction is different from those specified, and/or to gain a comprehensive R-value calculation and technical information of your project, please consult the Kingspan Insulation Technical Service Department for assistance. Call 1300 247 235 and press "2" to speak with Technical services, email technical@kingspaninsulation.com.au, or use the online contact form.


Assumption and Key

NCC 2019 prescribes different methods to determine Total R-value Calculations for Volume 1 and Volume 2.

The R-values shown are Total R-values for the building element as required by the Energy Provisions of the National Construction Code, calculated in accordance with AS/NZS 4859.2 2018 & NZS 4214, as required.

Residential Metal and Tiled Roof

View System R-value

General Requirements

  1. Fit Kingspan AIR-CELL neatly around doors, windows, and any penetrations, and tape if necessary to prevent air leakage.
  2. When taping a plastic squeegee or blade must be used to apply appropriate pressure to the tape. Surfaces must be dry and free from dust, oil or grease prior to taping (please refer to brochure ‘Kingspan Insulation Tape’ for further information).
  3. Leave minimum 100 mm clearance around heat producing flues or light fittings (refer to light fitting manufacturer).
     
The instructions in this document are guidelines only and should be interpreted with consideration for the specific building design. The installation of Kingspan AIR-CELL should be in conformance with the applicable clauses from AS 3999 and AS/NZS 4200.2 unless otherwise specified.
 
Kingspan AIR-CELL can be damaged by intense heat above 105° C and contact with sparks and flame from blow torches, welders, cutting tools, etc. must be avoided.
 
The installer must make due provision for safety when installing Kingspan AIR-CELL in any application.

Safety Information

View Safety Information

Handling & Storage

View Instructions

PDF Format

CAD PDF - Residential Metal Roof_Insulwhite

CAD PDF - Residential Tiled Roof_Insulwhite

DWG Format

CAD DWG - Residential Metal Roof_Insulwhite

CAD DWG - Residential Tiled Roof_Insulwhite

PSI - AIR-CELL Foam Range

Management Standards

Standard Management System
BS / I.S. ISO 9001:2008 Quality Management
AS/NZS ISO 14001:2004 Environmental Management


Product Specifications

Property Test Method / Standard Specification Classification
Flammability Index AS 1530.2 ≤ 5 Low
Material R-value ASTM C518 at 23oC 0.15 m²·K/W -
IR Emittance AS/NZS 4201.5 Reflective Face: 0.03
White Face: N/A
IR Reflective
IR Non- Reflective
IR Emittance - - Category RN
Burst Strength AS 3706.4 (CBR) 1.0 kN -
Vapour Control ASTM E96 Vapour Barrier
< 0.020 µg/N.s
Class 2
Water Control AS/NZS 4201.4 Pass Water Barrier
Moisture Shrinkage AS/NZS 4201.3 < 0.5% -
Dry Delamination AS/NZS 4201.1 Pass -
Wet Delamination AS/NZS 4201.2 Pass -
Surface Water Absorbency AS/NZS 4201.6 < 100g/m2 Low
Corrosion Resistance AS/NZS 4859.1:2018 App. E Pass -
Electrical Conductivity AS/NZS 200.1:2017 - c.5.3.1.2 10MΩ Electrically Conductive
 

Environmental Data Table

Aspect Characteristic
Recyclability Waste not recyclable. Roll width to suit most applications to minimise site waste
Re-usability Re-usable if removed with care (long term of service expected)
Water Use No water used in Kingspan Insulation's manufacturing process
Ozone Depleting Substances None present in the finish product or in Kingspan Insulation's manufacturing process
Packaging Contains approximately 10% recycled product. Packaging is 100% recyclable
Embodied Energy 43 MJ/m² approximately

Latest Case Studies

Do you need help and advice on your project?

Our teams are dedicated to helping you make process as easy as possible and ensure you get the right materials for your needs.

Contact Us

Contact Information

Kingspan Insulation Australia

Kingspan Insulation operates Australia wide. Contact us to find your local State Representative. For any enquiries, call 1300 247 235 or send an email to info@kingspaninsulation.com.au.

Head Office

25 Oherns Road,

Somerton, VIC

3062

Call: 1300 247 235

Fax: 1300 247 329