Firemaster_assembled

Firemaster

Firemaster offers a total internal wall and ceiling solution that is ideally suited for non load bearing internal partition walls and ceilings. It provides a tested fire resistance to match the performance required for internal firewalls, protected zones, ceilings and compartmentation walls.

All Firemaster wall and ceiling panels are manufactured with a stone wool core that provides built in passive fire protection, structural strength, robustness and low environmental impact. The panels are available in a wide range of finishes including a foodsafe coating, providing a smooth, anti-static internal surface.

All Firemaster systems can be integrated with tested and approved fire, acoustic and security steel doors for a complete fire resistant solution.
All Firemaster systems can be integrated with tested and approved fire, acoustic and security steel doors for a complete fire resistant solution.

Firemaster Products

Firemaster Wall Lite

This system gives the optimum balance between fire performance, cost and weight and has been designed specifically as a practical, contractor-friendly solution. There’s no better choice when fire resistance is specified and speed, flexibility and cost effectiveness is demanded and can provide up to 90 minutes fire resistance.

Firemaster Wall Extra

Firemaster Extra is the product of choice when the demand is for a 2 hour fire resistance internal wall panel. Fully tested and independently certified durability, structural integrity and fire performance is at the heart of Firemaster Extra. This panel system is ideal for a wide range of applications including cold store rooms and food processing plants.

Firemaster Wall Ultima

Firemaster Ultima provides the demanding solution for fire walls and compartmentation in high risk areas where up to 4 hours’ fire resistance is required. Business continuity and life safety are dramatically increased thanks to the integrity and insulation of this unique system making it ideal for use in high risk buildings such as Data Centres.

Firemaster Ceiling

Firemaster Ceiling is a class leading fire-rated ceiling panel suitable for both walk on (access and maintenance) and non-walk on use. It’s the ideal solution to compartmentalise a building when protection and life safety are a priority.

Technical Information

Product Dimensions
Fire Performance
Thermal Performance
Core
Materials
Thickness mm 75 100 125 150 175 200 240
300
Extra kg/m² 17.5 20.5 23.5 26.5 29.5 32.5 37.3
42
Ultima kg/m² 19.9 22.9 25.9 28.9 31.9 34.9 39.7 44.4
Ceiling kg/m² 18.7 21.7 24.7 27.7 30.7 33.7 38.5 43.2
Firemaster wall and ceiling panels, with their non-combustible stone wool core can deliver up to 4 hours fire performance when tested and assessed in accordance with AS1530.4. Tested fire performance is of the complete wall construction not individual components and hence gives reassurance of how the wall would protect in an actual fire event.
 
Product Core Thickness (mm) Insulation Integrity
Firemaster Wall Extra 75 60 60
100* 120 120
125 120 120
150 120 120
175 120 120
200 120 120
240 120 120
Firemaster Wall Ultima 150** 240 240
175** 180 180
175** 240 240
200 240 240
240 240 240
Firemaster Ceiling 100 60 60
125 60 60
150** 120 120


*Interlocking joints stitched at 3m centers
**Panel joints stitched on both sides at 300mm centres using 3.8mm diameter x 16mm long stainless-steel rivets. 0.7mm steel face to both sides
 
The R-Values presented are Total R-Values for the building element as required by the Energy Provisions of the National Construction Code, calculated in accordance with AS/ NZS 4859.2 2018.
 
Declared Product R-Value is calculated in accordance with AS/NZS 4859.1:2018 as required for compliance to the National Construction Code 2019.
 
Firemaster Extra & Firemaster Ultima
Panel Nominal Thickness (mm) Product R-Value  (m²K/W) at 23°C Total R-Value (m²K/W) Total R-Value (m²K/W)
Heat Flow Out (winter) Heat Flow In (summer)
75 1.52 1.76 1.61
100 2.04 2.31 2.11
125 2.57 2.87 2.62
150 3.10 3.43 3.13
175 3.65 4.01 3.65
200 4.17 4.55 4.14
240 5.02 5.45 4.95

Firemaster Ceiling
Panel Nominal Thickness (mm) Product R-Value  (m²K/W) at 23°C Total R-Value (m²K/W) Total R-Value (m²K/W)
Heat Flow Out (Winter) Heat Flow In (Summer)
75 1.52 1.75 1.65
100 2.04 2.30 2.15
125 2.57 2.86 2.66
150 3.10 3.42 3.17
175 3.65 4.00 3.69
200 4.17 4.54 4.18
240 5.02 5.44 4.99


Firemaster is manufactured, tested and packaged in conformance with AS/NZS 4859.1 :2018
 
Firemaster panels are manufactured with a 120kg/m³ stone wool core which is specifically designed to be used in insulated panels where excellent thermal and fire resistance properties are required.  The core material is specifically treated to be water- repellent, non-hygroscopic and non-capillary.
 
Exterior Sheet

Firemaster Extra & Ultima - Substrate to be minimum 0.5mm thick coated steel to AS 1397
Firemaster Ceiling- Substrate to be minimum 0.7mm thick coated steel to AS 1397
Coating  : White Polyester lining RAL 9010 or Advantica Foodsafe RAL 
 
Interior Liner Sheet

Firemaster Extra & Ultima - Substrate to be minimum 0.5mm thick coated steel to AS 1397
Firemaster Ceiling- Substrate to be minimum 0.5mm thick coated steel to AS 1397
Coating: White Polyester lining RAL 9010 or Advantica Foodsafe RAL
 
For a range of colours available, please contact your local Kingspan representative.