Integrates multiple cassettes onto a single insulated panels. Each individual cassette can be a different colour and size.

With a wide range of finishes and complete colour freedom, individual cassettes on a panel can be finished in a different post-powder coating and in any BS or RAL colour of your choice and can vary in size.
" frameborder="0" allowfullscreen>

Kreate install video

  • Variable panel sizes, cassette arrangement and colour options
  • Rapid installation 
  • Panels up to 6000mm in length
  • Reduced Health & Safety risks due to less time spent working at height
  • All the advantages of a high performance insulated panel system
  • No façade fire stops required

Installation- as easy as 1,2,3!

Download
2015_EDINBURGH AIRPORT_48_KRT_UK.jpg

Technical Details

Kreate

Integrating multiple aluminium cassettes on a single insulated panel, with a wide range of finishes and complete colour freedom. Individual cassettes on a panel can be finished in a different post-powder coating and in any BS or RAL colour of your choice and can vary in size. Architectural powder coating to Qualicoat standard or Qualicoat ‘Seaside’ standard.

Dimensions

Panel: Sizes are from 600mm width x 1200mm length to 1200mm width x 6000mm length.
Cassette: Sizes from 307mm width x 307mm length to 1174mm width x 3800mm length. Various sizes and colours can be used on any one panel.
Both the horizontal and vertical joints between each cassette / panel are 24mm and formed using an EPDM push-in gasket.
Kreate_Dimensions_NoEnglish
Note: The weight of a BENCHMARK Kreate panel is determined by the cassette design arrangement. Please contact the BENCHMARK Technical Department for further information.

Thermal Insulation
Kreate panels have a Thermal Transmittance (U-value), calculated using the method required by the Building Regulations Part L2 (England & Wales) and Building Standards Section 6 (Scotland), of:
*The core thickness is measured from the internal liner to the line of the cassettes. The insulation immediately behind the cassettes is not taken into account.
U - Value
Overall Thickness (mm) 104 124 174
Core Thickness (mm) 80 100 150
U-Value (W/m 2K) 0.26 0.21 0.13
Note: The weight of a BENCHMARK Kreate panel is determined by the cassette design arrangement. Please contact the BENCHMARK Technical Department for further information.

Thermal Insulation
Kreate panels have a Thermal Transmittance (U-value), calculated using the method required by the Building Regulations Part L2 (England & Wales) and Building Standards Section 6 (Scotland), of:
*The core thickness is measured from the internal liner to the line of the cassettes. The insulation immediately behind the cassettes is not taken into account.
U - Value
Overall Thickness (mm) 104 124 174
Core Thickness (mm) 80 100 150
U-Value (W/m 2K) 0.26 0.21 0.13
Kreate panels are FIREsafe, and approved by the Loss Prevention Certification Board (LPCB) to LPS 1181 Grade EXT-B.

Panel Core
Kreate is ECOsafe with a polyisocyanurate (PIR) insulation core that contains no CFC’s or HCFC’s and has a low global warming potential.
 
  • Façade: The cassettes are manufactured from 2mm aluminium. Both vertical and horizontal joints between cassettes within each panel are also aluminium
  • Internal Liner - Coatings -
    • Standard: polyester coating developed for use for the internal lining of  insulated panels.
    • Standard colour is “bright white” with an easily cleaned surface.
    • Kingspan CLEANsafe: coating developed for use where the liner is exposed to foodstuffs and is regularly cleaned. Colour white.
    • Kingspan AQUAsafe: coating for internal high humidity environments. Colour white.

Single Span Condition

Uniformly Distributed Loads kN/m²  - Span L in metres
Panel
Thickness
(mm)
Load
Type
                     
80 Pressure 5.39 4.85 4.26 3.64 3.21 2.78 2.47 2.15 1.92 1.69 1.52
80 Suction 4.98 4.03 3.46 2.88 2.53 2.17 1.93 1.69 1.52 1.35 1.23
100 Pressure 5.39 4.85 4.48 4.10 3.83 3.56 3.35 2.96 2.67 2.37 2.15
100 Suction 5.36 4.78 4.10 3.42 3.00 2.57 2.29 2.00 1.80 1.60 1.46
150 Pressure 5.39 4.85 4.48 4.10 3.83 3.56 3.35 2.96 2.67 2.37 2.15
150 Suction 5.36 4.78 4.10 3.42 3.00 2.57 2.29 2.00 1.80 1.60 1.46
 

Double Span Condition

Uniformly Distributed Loads kN/m²  - Span L in metres
Panel
Thickness
(mm)
Load
Type
                     
80 Pressure 5.39 4.85 4.48 4.10 3.67 3.23 2.77 2.30 2.01 1.71 1.52
80 Suction 4.98 4.03 3.46 2.88 2.53 2.17 1.93 1.69 1.52 1.35 1.23
100 Pressure 5.39 4.85 4.48 4.10 3.83 3.56 3.28 2.99 2.60 2.20 1.94
100 Suction 5.36 4.78 4.10 3.42 3.00 2.57 2.29 2.00 1.80 1.60 1.46
150 Pressure 5.39 4.85 4.48 4.10 3.83 3.56 3.28 2.99 2.60 2.20 1.94
150 Suction 5.36 4.78 4.10 3.42 3.00 2.57 2.29 2.00 1.80 1.60 1.46
 

Notes

For each value individual and combined load cases with appropriate load factors and temperatures have been considered.
  • Please contact the BENCHMARK Technical Department for details.
  • The table is for dark coloured panels.
  • The following deflection limits have been used:
  • Pressure Loading L/100
  • Suction Loading L/100
  • For intermediate values linear interpolation may be used.The actual wind suction load resisted by the panel is dependent upon the number of fasteners used and material of the rail. The fastener calculation should be carried out in accordance with the appropriate standard. For further advice please contact BENCHMARK Technical Services.
  • The allowable tolerance between bearing planes of adjacent supports is L/600, where L is the distance between supports.
  • Load span tables for spans outside of those shown are available from the BENCHMARK Technical Department.

Kreate Product Data Sheet

Project details

In main photograph, MedDX, Skylon Park. Product: Kreate. Architect: St Paul's Associates Ltd Read More

We use cookies on our website www.kingspan.com. To find out more about the cookies we use, or to change your cookie preferences i.e. to remove your consent to our use of certain categories of cookies, please visit our Cookie Policy & Control page.

Please click "Accept and close" to accept the use of cookies on our website. If you do not click "Accept and close" but continue to use this website: you thereby consent to the use of all Kingspan's cookies and third party cookies for the purposes of improving performance, improving functionality and audience measurement, in accordance with the terms laid out in our Cookie Policy & Control page; and we will assume that you have read and understood our Cookie Policy & Control page.